Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CPE AMERICA RENTALS, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CPE AMERICA RENTALS, LLC in 655 WEST LYTELL STREET, METTER, GA 30439 (NAICS 423810). OSHA activity number 342310026.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CPE America Rentals, LLC — free Get an email when a new federal OSHA severe-injury report for CPE America Rentals, LLC is published. One employer, no account, unsubscribe in one click.
Site address
655 WEST LYTELL STREET
City
METTER
State
GA
ZIP
30439
Mailing
655 WEST LYTELL STREET, METTER, GA 30439
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423810
Employees
11
Ownership type
A

5 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 2 exposed
Issued
May 30, 2017
Abate by
Jun 23, 2017
Penalty
Initial $2,173 · Current $1,304 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  (a) Throughout the facility, on or about May 1, 2017 and at times prior to, the employer did not implement a written respiratory protection program for two employees who were required to wear a 3M 52P71 half mask respirator while performing painting and welding activities at the facility, resulting in a respiratory hazard.
Recent events (2)
  • — I (S) $1303.8
  • — Z (S) $2173

1910.134 D01 I

Serious Gravity 1 1 instance 1 exposed
Issued
May 30, 2017
Abate by
Jun 23, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability:  (a)  Throughout the facility, on or about May 1, 2017 and at times prior to, the employer did not select an appropriate respirator for use beneath a welder's helmet, resulting in a respiratory hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
May 30, 2017
Abate by
Jun 23, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a) Throughout the facility, on or about May 1, 2017 and at times prior to, the employer did not provide medical evaluations for two employees who were required to wear a 3M 52P71 half mask respirator while performing painting and welding activities at the facility, resulting in a respiratory hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 1 1 instance 2 exposed
Issued
May 30, 2017
Abate by
Jun 23, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  (a) Throughout the facility, on or about May 1, 2017 and at times prior to, the employer did not provide fit tests for two employees who were required to wear a 3M 52P71 half mask respirator while performing painting and welding activities at the facility, resulting in a respiratory hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 II

Other-than-serious 1 instance 11 exposed
Issued
May 30, 2017
Abate by
Jun 23, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:  (a)  In the production area of the facility, on or about May 1, 2017, and at times prior to, the employer did not ensure that compressed gas cylinders containing argon and oxygen were secured in a way to prevent them from being knocked over resulting in a struck-by hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View CPE America Rentals, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342310026.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.