OSHA Inspection: ALL-WEATHER ROOFING COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALL-WEATHER ROOFING COMPANY, INC. in 3917 STATION ROAD, ERIE, PA 16510 (NAICS 238160). OSHA activity number 342341658.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch All-Weather Roofing Company, INC. — free Get an email when a new federal OSHA severe-injury report for All-Weather Roofing Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3917 STATION ROAD
City
ERIE
State
PA
ZIP
16510
Mailing
1248 WEST 17TH STREET, ERIE, PA 16502
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1910.28 B13 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 21, 2017
Abate by
Jul 18, 2017
Penalty
Initial $3,622 · Current $2,443 Reduced
29 CFR 1910.28(b)(13)(ii): When work is performed at least 6 feet (1.6 m) but less than 15 feet (4.6 m) from the roof edge, the employer did not ensure each employee is protected from falling by using a guardrail system, safety net system, travel restraint system, or personal fall arrest system.      A.)  All-Weather Roofing Company, Inc., 3917 Station Road, Erie, PA  16510, on or about May 10, 2017 and times prior thereto:  Employees were exposed to a fall hazard of 6.4-feet and 18.9-feet when performing roofing activities that included, but were not limited to, the removal of roofing materials.  Employees were not utilizing a means or methods of fall protection.
Recent events (2)
  • — I (S) $2442.5
  • — Z (S) $3622

1910.304 B03 II A

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 21, 2017
Abate by
Jul 18, 2017
Penalty
Initial $2,897 · Current $2,443 Reduced
29 CFR 1910.304(b)(3)(ii)(A): All 125-volt, single-phase, 15, 20 and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel did not have ground-fault circuit-interrupter protection for personnel.    A.)  All-Weather Roofing Company, Inc., 3917 Station Road, Erie, PA  16510, on or about May 10, 2017 and times prior thereto:  Employees were utilizing electrical power tools including, but not limited to, a circular saw to perform roofing activities.  The employees were not utilizing a GFCI when utilizing the electrical power tools.  The company does not have an assured equipment grounding conductor program
Recent events (2)
  • — I (S) $2442.5
  • — Z (S) $2897

View All-Weather Roofing Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342341658.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.