Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: APPLIED MOLDING TECHNOLOGIES, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of APPLIED MOLDING TECHNOLOGIES, LLC. in 509 WISCONSIN AVENUE SOUTH, FREDERIC, WI 54837 (NAICS 333249). OSHA activity number 342345477.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Applied Molding Technologies, LLC. — free Get an email when a new federal OSHA severe-injury report for Applied Molding Technologies, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
509 WISCONSIN AVENUE SOUTH
City
FREDERIC
State
WI
ZIP
54837
Mailing
509 WISCONSIN AVENUE SOUTH, FREDERIC, WI 54837
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333249
Employees
19
Ownership type
A

17 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 6 exposed
Issued
Oct 27, 2017
Abate by
Nov 28, 2017
Penalty
Initial $2,897 · Current $2,897
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees are exposed to struck by injuries from utilizing damaged racking systems:  (a) Warehouse area; On or about May 22, 2017, employees were exposed to potential struck by hazards because damaged upright columns on a metal racking system were not isolated from use, unloaded, repaired, and/or replaced once damage was identified.
Recent events (1)
  • — Z (S) $2897

1910.22 A01

Serious Gravity 5 3 instances 10 exposed
Issued
Oct 27, 2017
Abate by
Nov 15, 2017
Penalty
Initial $3,622 · Current $3,622
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition:  (a) Press area; Floors were not kept in an orderly manner to organize air hoses, flexible cords, and waterlines.
Recent events (1)
  • — Z (S) $3622

1910.22 A02

Serious Gravity 5 3 instances 10 exposed
Issued
Oct 27, 2017
Abate by
Nov 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(2): The floor of each workroom was not maintained in a clean and, to the extent feasible, in a dry condition:    (a) Press area; Floors were not kept clean and dry to prevent accumulation of leaking water and hydraulic oil.
Recent events (1)
  • — Z (S) $0

1910.22 D01

Serious Gravity 5 2 instances 10 exposed
Issued
Oct 27, 2017
Abate by
Nov 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): The employer did not ensure that walking-working surfaces were inspected, regularly and as necessary, and maintained in a safe condition:  (a) Press area; Floors in the press area were not inspected regularly enough, so as to prevent hazards related to wet floors and items that were not stored in an orderly fashion.
Recent events (1)
  • — Z (S) $0

1910.28 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Oct 27, 2017
Abate by
Nov 13, 2017
Penalty
Initial $3,622 · Current $3,622
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2m) or more above a lower level was protected from falling by guardrail systems, safety net system, or personal fall arrest system:  (a) Chiller mezzanine above utility closet; A guardrail or other acceptable means of fall protection was not provided for an open side on the elevated mezzanine.
Recent events (1)
  • — Z (S) $3622

1910.147 C01

Serious Gravity 10 1 instance 6 exposed
Issued
Oct 27, 2017
Abate by
Nov 28, 2017
Penalty
Initial $5,070 · Current $5,070
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  (a) Throughout the facility; The employer did not establish a program consisting of energy control procedures, employee training, and periodic inspections as required.
Recent events (1)
  • — Z (S) $5070

1910.147 C07 I

Serious Gravity 10 1 instance 6 exposed
Issued
Oct 27, 2017
Abate by
Nov 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program were understood by authorized, affected, and other employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by authorized employees:   (a) Throughout the facility; Authorized level energy isolation (lockout) training was not provided for employees to inform them of the means and methods to use for isolating hazardous energy sources before they performed servicing, maintenance, and setup activities on equipment including, but not limited to, extrusion presses which had multiple energy sources including pneumatic, hydraulic, electric, and thermal.  (b) Throughout the facility; Affected level energy isolation (lockout) training was not provided to inform employees of the purpose and function of the energy control program.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 2 instances 8 exposed
Issued
Oct 27, 2017
Abate by
Nov 28, 2017
Penalty
Initial $5,070 · Current $5,070
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Press area; Guarding was not provided on extrusion press 3 to protect employees from hazards associated with rotating parts and thermal energy while hand loading poly bead material into the press.
Recent events (1)
  • — Z (S) $5070

1910.219 C02 I

Serious Gravity 10 1 instance 8 exposed
Issued
Oct 27, 2017
Abate by
Nov 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:  (a) Press area; Guarding was not provided for the horizontal shaft that provides power to the barrel screw in press 3.
Recent events (1)
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 27, 2017
Penalty
Initial $3,622 · Current $3,622
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:  (a) Production area; Guarding on a bandsaw was not adjusted to protect against contacting the unused portion of blade.
Recent events (1)
  • — Z (S) $3622

1910.303 G02 I

Serious Gravity 5 3 instances 10 exposed
Issued
Oct 27, 2017
Abate by
Nov 13, 2017
Penalty
Initial $4,346 · Current $4,346
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:  (a) Press area; Electrical connections on a spliced flexible cord were not protected by an enclosure, elevation, or other acceptable means.
Recent events (1)
  • — Z (S) $4346

1910.305 G02 II

Serious Gravity 5 1 instance 10 exposed
Issued
Oct 27, 2017
Abate by
Nov 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used in continuous lengths without splice or tap:  (a) Press area; An extension cord (flexible cord set) was spliced.
Recent events (1)
  • — Z (S) $0

1910.305 B01 I

Serious Gravity 5 1 instance 10 exposed
Issued
Oct 27, 2017
Abate by
Nov 13, 2017
Penalty
Initial $2,897 · Current $2,897
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter were not effectively closed:  (a) Press area; Conductors entering a box were not protected from abrasions, and   (b) Press area; The opening where conductor wires entered a box was not effectively closed.
Recent events (1)
  • — Z (S) $2897

1910.305 G02 III

Serious Gravity 5 2 instances 10 exposed
Issued
Oct 27, 2017
Abate by
Nov 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  (a) Press area; Strain relief was not provided for flexible cords on equipment, including but not limited to a poly bead media dryer and wet/dry type vacuum.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Repeat Gravity 5 2 instances 10 exposed
Issued
Oct 27, 2017
Abate by
Nov 13, 2017
Penalty
Initial $8,691 · Current $8,691
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  (a) Press area; Modified extension cord sets were used as a substitute for permanent wiring on press 1 and 2.  The Applied Molding Technologies, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(g)(1)(iv)(A), which was contained in OSHA inspection number 1017787, citation number 1, item number 2b and was affirmed as a final order on July 29, 2015, with respect to a workplace located at 509 Wisconsin Avenue South in Frederic, WI.
Recent events (1)
  • — Z (R) $8691

1904.29 B01

Other-than-serious 1 instance 10 exposed
Issued
Oct 27, 2017
Abate by
Nov 15, 2017
Penalty
Initial $724 · Current $724
29 CFR 1904.29(b)(1):  A Log of all recordable work-related injuries and illnesses (OSHA Form 300 or equivalent) was not completed in the detail required by the regulation:  (a) Throughout the facility; On or about May 22, 2017, a log of work-related injuries and illnesses (OSHA Form 300) was not developed for calendar year 2017.
Recent events (1)
  • — Z (O) $724

1904.40 A

Other-than-serious 1 instance 10 exposed
Issued
Oct 27, 2017
Abate by
Nov 15, 2017
Penalty
Initial $724 · Current $724
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours:  (a) Throughout the establishment; On or about May 22, 2017, copies of work-related injury and illness logs (forms 300 and 300-A) were not provided to OSHA within four hours of request for calendar years 2013, 2014, 2015, 2016, or 2017.
Recent events (1)
  • — Z (O) $724

View Applied Molding Technologies, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342345477.