OSHA Inspection: CROWN EQUIPMENT CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CROWN EQUIPMENT CORPORATION in 424 W MONROE ST., NEW BREMEN, OH 45869 (NAICS 333924). OSHA activity number 342354156.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Crown Equipment Corporation for free Get an email when a new federal OSHA severe-injury report for Crown Equipment Corporation is published. One employer, no account, unsubscribe in one click.
Site address
424 W MONROE ST.
City
NEW BREMEN
State
OH
ZIP
45869
Mailing
44 S. WASHINGTON ST., NEW BREMEN, OH 45869
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333924
Employees
300
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 10 1 instance 22 exposed
Issued
Sep 27, 2017
Abate by
Oct 6, 2017
Penalty
Initial $12,675 · Current $8,873 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program was understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees.     a. Crown Equipment Corporation located in New Bremen, Ohio:  On or about May 22, 2017 the employer did not ensure employees using a coolant hose to spray metal chips from the cutting area of the Amada HFA 400W horizontal bandsaw, were adequately trained to lock out the saw and material clamp prior to performing the cleaning operation.
Recent events (2)
  • · I (S) $8873
  • · Z (S) $12675

1910.147 D

Deleted Serious Gravity 10 1 instance 22 exposed
Issued
Sep 27, 2017
Abate by
Oct 6, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedures for the application of energy control (the lockout or tagout procedures) did not cover the following elements and actions and shall be done in the following sequence.  a. Crown Equipment Corporation located in New Bremen, Ohio:  On or about May 22, 2017 the employer did not ensure employees using a coolant hose to spray metal chips from the cutting area of the Amada HFA 400W horizontal bandsaw, locked out the saw and material clamp prior to performing the cleaning operation.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Crown Equipment Corporation's full OSHA safety record →