SCHULENBURG, TX —
OSHA Inspection: PRIME PRODUCTS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PRIME PRODUCTS, INC. in 407 E HWY 90, SCHULENBURG, TX 78956 (NAICS 326160). OSHA activity number 342363231.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRIME PRODUCTS, INC.
- Site address
- 407 E HWY 90
- City
- SCHULENBURG
- State
- TX
- ZIP
- 78956
- Mailing
- P.O. BOX 100, SCHULENBURG, TX 78956
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326160
- Employees
- 100
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jul 20, 2017
- Abate by
- Aug 9, 2017
- Penalty
- Initial $5,070 · Current $3,042 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about May 31, 2017, the employer did not ensure energy control procedures were developed for the newer injection molding machines. Employees perform maintenance and mold changes on the injection molding machines. Employees were exposed to the hazard of being caught-in the machine and/or an electrical shock hazard from an unexpected start-up of the machine. Energy control procedures were not developed for such machines as, but not limited to: 1. Sumitomo Demag SE385EV-A, injection molding machine. Some potential energy sources for this machine are electrical, hydraulic and pneumatic. 2. Sumitomo SE180E, injection molding machine. Some potential energy sources for this machine are electrical, hydraulic and pneumatic.
Recent events (2)
- — I (S) $3042
- — Z (S) $5070
1910.147 C06 I
- Issued
- Jul 20, 2017
- Abate by
- Aug 9, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about May 31, 2017, the employer did not perform a periodic inspection of the energy control at least annually. Employees perform such operations as maintenance mold changes on the injection molding machine. Employees were exposed to the hazard of being caught-in the machine and/or an electrical shock hazard from an unexpected start-up of the machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Jul 20, 2017
- Abate by
- Aug 9, 2017
- Penalty
- Initial $7,605 · Current $4,563 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: On or about May 31, 2017, the employer failed to ensure the employees were trained and they had the knowledge and skills for the safe application, usage and removal of energy control devices when maintaining, cleaning, unjamming equipment such as, but not limited to all the injection molding machines. Employees were exposed to the hazard of being caught-in the machine and/or an electrical shock hazard from an unexpected start-up of the machine.
Recent events (2)
- — I (S) $4563
- — Z (S) $7605
1910.212 A01
- Issued
- Jul 20, 2017
- Abate by
- Aug 9, 2017
- Penalty
- Initial $3,802 · Current $2,281 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about May 31, 2017, in the maintenance department, the 15 inch Wilton drill press did not have the rotating chuck and bit guarded. Employees make parts for the machines in the plant. The employees were exposed to the hazard of being caught-in the rotating chuck and bit.
Recent events (2)
- — I (S) $2281.2
- — Z (S) $3802
1910.212 B
- Issued
- Jul 20, 2017
- Abate by
- Jul 31, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) On or about May 31, 2017, in the maintenance department, the 15 inch Wilton drill press was not anchored to the floor. Employees use the drill press to make parts. Employees exposed to the hazard of being struck-by the falling drill press or the material being worked on shifts from unstable drill press. b) On or about May 31, 2017, in the maintenance department, the Baldor pedestal grinder was not anchored to the floor. Employees use the pedestal grinder. Employees exposed to the hazard of being struck-by the falling pedestal grinder or the material being worked on shifts from unstable grinder.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 C04 II
- Issued
- Jul 20, 2017
- Abate by
- Jul 31, 2017
- Penalty
- Initial $6,338 · Current $3,803 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered. On or about May 31, 2017, at the Sumitomo SE180EV injection molding machine conveyor, the rotating unprotected keyway shaft was protruding out approximately 2.5 inches. Employees work and walk by the conveyor with the rotating protruding shaft. Employees exposed to the hazard of being caught-in the rotating protruding shaft.
Recent events (2)
- — I (S) $3802.8
- — Z (S) $6338
1910.219 I02
- Issued
- Jul 20, 2017
- Abate by
- Jul 31, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(i)(2): Revolving surfaces of shaft coupling(s) were not covered by a safety sleeve: On or about May 31, 2017, at the Sumitomo SE180EV injection molding machine conveyor, there was an unprotected rotating coupling shaft that was not protected or guarded. Employees work and walk by the rotating shaft on the conveyor. Employees exposed to the hazard of being caught-in rotating shaft.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B07
- Issued
- Jul 20, 2017
- Abate by
- Jul 31, 2017
- Penalty
- Initial $7,605 · Current $4,563 Reduced
General-duty citation text
29 CFR 1910.303(b)(7): Electric equipment was not installed in a neat and workmanlike manner: a) On or about May 31, 2017, at the Cincinnati Milacron-Fanuc also called Roboshot #2 110R, the electrical wiring was not installed in a neat and workman like manner. The internal conductors were pulled out of their outer sheath and wired together. Employees exposed to the hazard of an electrical shock from 120 volts. b) On or about May 31, 2017, at the Maquire Blender, the electrical wiring for the motor was exposed. The motor was operating and had exposed wiring. Employees exposed to the hazard of an electrical shock from 120 volts.
Recent events (2)
- — I (S) $4563
- — Z (S) $7605
1910.305 B01
- Issued
- Jul 20, 2017
- Abate by
- Jul 31, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1): Conductors entering boxes, cabinets, or fittings were not protected from abrasions; a) On or about May 31, 2017, at the Cincinnati Milacron UT220, the employer did not ensure the 120 volt conductors entering the box were protected against abrasion. Employees exposed to an electrical shock hazard. b) On or about May 31, 2017, at the Cincinnati Milacron UT220, the employer did not ensure the 208 volt conductors entering the box were protected against abrasion. Employees exposed to an electrical shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 G05
- Issued
- Jul 20, 2017
- Abate by
- Jul 26, 2017
- Penalty
- Initial $3,802 · Current $2,281 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective: On or about May 31 2017, the shop floor area, the Pro Fitter 20 inch oscillating floor fan did not have continuous and permanent grounding. Employees using the fan to keep cool. Employee(s) exposed to the hazard of a potential electrical shock. The Pro Fitter fan was 120 volts, model SFSI-500SWI.
Recent events (2)
- — I (S) $2281.2
- — Z (S) $3802
1910.305 B01 II
- Issued
- Jul 20, 2017
- Abate by
- Jul 26, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) On or about May 31, 2017, two metal junction boxes installed on the injection molding machine were missing knockout plugs. The junction boxes were 208 volt each. Employees work around and must pass by the two junction boxes. Employees exposed to the hazard of an electrical shock. (b) On or about May 31, 2017, at the Cincinnati Milacron UT220, a 208 volt disconnect panel box was missing a knockout plug on the side of the box. Employees operate the machine and work around the disconnect box. Employees exposed to the hazard of an electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 J02 I
- Issued
- Jul 20, 2017
- Abate by
- Jul 26, 2017
- Penalty
- Initial $3,802 · Current $2,281 Reduced
General-duty citation text
29 CFR 1910.305(j)(2)(i): Receptacles, cord connectors and attachment plugs were not constructed so no receptacles may be installed so as to require an energized attachment plug as its source of supply: On or about May 31, 2017, at the AEKI #2, the employer did not ensure a metal junction box that is manufactured to be permanently mounted was not used as an extension cord. The box was made into extension cord for a temporary electrical source for the AEKI #2. Employees exposed to an electrical shock hazard. In the alternative: 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:
Recent events (2)
- — I (S) $2281.2
- — Z (S) $3802
1910.219 F03
- Issued
- Jul 20, 2017
- Abate by
- Jul 31, 2017
- Penalty
- Initial $7,605 · Current $4,563 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven 7 feet or less above floors or platforms were not enclosed: On or about May 31, 2017, at the Sumitomo Demag SE 385EV, injection molding machine conveyor, the employer did not ensure that the sprockets and chain were guarded. Employees working near the unguarded chain and sprockets when picking up plastic cups and packing them. Employees exposed to the hazard of being caught-in the rotating chain and sprockets. The Prime Products, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.219(f)(3), which was contained in OSHA inspection number 1059373, citation number 1, item number 4, and was affirmed as a final order on October 16, 2015, with respect to a workplace located at 407 E Hwy US 90, Schulenburg, TX 78956.
Recent events (2)
- — I (R) $4563
- — Z (R) $7605
More inspections at Prime Products, INC.
View Prime Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326160)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342363231.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.