Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: SOUTHFRESH AQUACULTURE, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SOUTHFRESH AQUACULTURE, LLC in 1231 US HIGHWAY 43, EUTAW, AL 35462 (NAICS 311412). OSHA activity number 342375201.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southfresh Aquaculture, LLC for free Get an email when a new federal OSHA severe-injury report for Southfresh Aquaculture, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1231 US HIGHWAY 43
City
EUTAW
State
AL
ZIP
35462
Mailing
PO BOX 191, EUTAW, AL 35462
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311412
Employees
175
Ownership type
Private (A)

4 citations on file for this inspection.

1910.147 C02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 8, 2017
Abate by
Sep 20, 2017
Penalty
Initial $9,778 · Current $6,000 Reduced
29 CFR 1910.147(c)(2)(ii): The employer's tagout energy control program procedures did not successfully comply with 29 CFR 1910.147(c)(3) and no lockout was provided for employee protection:    a)  At Ice House, Southfresh Aquaculture, Eutaw, Alabama:  On or about May 30, 2017 and at times prior; the employer exposed employees to caught-by hazards in that employees were allowed to place part of his/her body above the rake portion of the machine without first locking out the machine to prevent accidental start-up.
Recent events (2)
  • · I (S) $6000
  • · Z (S) $9778

1910.147 C06 I

Serious Gravity 5 1 instance 11 exposed
Issued
Sep 8, 2017
Abate by
Oct 4, 2017
Penalty
Initial $8,149 · Current $6,000 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:  a)  At Southfresh Aquaculture, Eutaw, Alabama:  On or about June 5, 2017 and at times prior; the employer did not ensure that machine specific lockout procedures were annually audited/evaluated to ensure that the procedures effectively control all applicable energy sources.
Recent events (2)
  • · I (S) $6000
  • · Z (S) $8149

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Sep 8, 2017
Abate by
Oct 4, 2017
Penalty
Initial $8,311 · Current $6,000 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by an ingoing nip point or rotating parts:   a)  At Ice House, Southfresh Aquaculture, Eutaw, Alabama:  On or about June 5, 2017 and at times prior; the employer exposed his employees to caught-by and pinch point hazards in that employees were allowed to work at the rear of the ice house which did not have a guard covering the rake portion of the machine.
Recent events (2)
  • · I (S) $6000
  • · Z (S) $8311

1910.303 G02 I

Serious Gravity 5 1 instance 10 exposed
Issued
Sep 8, 2017
Abate by
Oct 4, 2017
Penalty
Initial $6,926 · Current $1,900 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a)  At Maintenance Shop, Southfresh Aquaculture, Eutaw, Alabama:  On or about June 5, 2017 and at times prior; the employer exposed his employees to electrical hazards in that employees were allowed to work around open breaker slots exposing live 480 volt buss bars inside the  HMP-C electrical panel.
Recent events (2)
  • · I (S) $1900
  • · Z (S) $6926

View Southfresh Aquaculture, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342375201.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.