GREELEY, CO —
OSHA Inspection: RANGER ENERGY SERVICES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RANGER ENERGY SERVICES in SRCGCC10VD API 05-123-34541, AIMS PAD, GREELEY, CO 80632 (NAICS 213112). OSHA activity number 342375672.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RANGER ENERGY SERVICES
- Site address
- SRCGCC10VD API 05-123-34541, AIMS PAD
- City
- GREELEY
- State
- CO
- ZIP
- 80632
- Mailing
- 800 GESSNER STE. 1000, HOUSTON, TX 77024
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 653
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 D01 III
- Issued
- Nov 27, 2017
- Abate by
- Dec 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard in the workplace: (a) Ranger Energy Services, SRCGCC10VD API 05-123-34541, Aims Pad, Greeley, CO 80632: On and preceding 5/30/17, the employer did not identify and evaluate the respiratory hazard in the workplace. Employees performed rigging up and nippling up procedures at a well site and tank battery storage site. The rig manager wore a 4-gas meter, but the employees wore only hydrogen sulfide monitors. The employer did not identify and evaluate the respiratory hazards, such as, but not limited to oxygen deficient atmospheres, and the presence of hydrocarbon vapors such as benzene. This condition exposed employees to respiratory hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H03 I
- Issued
- Nov 27, 2017
- Abate by
- Dec 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(i): The employee training did not include the methods and observations used to detect the presence or release of a hazardous chemical in the work area: (a) Ranger Energy Services, SRCGCC10VD API 05-123-34541, Aims Pad, Greeley, CO 80632: On and preceding 5/30/17, the employer did not provide training to include the methods and observations used to detect the presence or release of a hazardous chemical in their work area. Employees performed rigging up and nippling up procedures for a well site and tank battery site. The employer did not adequately train employees about the methods and observations used to detect chemical hazards in the workplace, such as, but not limited to benzene and other hydrocarbons. This condition exposed employees to chemical and respiratory hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Ranger Energy Services
View Ranger Energy Services's full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342375672.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.