Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RANGER ENERGY SERVICES

Special Programs inspection · Safety discipline

On , OSHA opened a special Programs safety inspection of RANGER ENERGY SERVICES in BALMORHEA ST 32-15B 6H, 31.37622 LAT; -103.47091 LONG, PECOS, TX 79772 (NAICS 213111). OSHA activity number 348141011.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ranger Energy Services — free Get an email when a new federal OSHA severe-injury report for Ranger Energy Services is published. One employer, no account, unsubscribe in one click.
Site address
BALMORHEA ST 32-15B 6H, 31.37622 LAT; -103.47091 LONG
City
PECOS
State
TX
ZIP
79772
Mailing
5801 EAST HIGHWAY 80, MIDLAND, TX 79705
Inspection type
Special Programs (K)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
213111
Employees
6
Ownership type
A

4 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 1 1 instance 6 exposed
Issued
Sep 4, 2025
Abate by
Sep 16, 2025
Penalty
Initial $5,064 · Current $5,064
29 CFR  1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i).  On or about March 25, 2025, on the rig floor; employees were not protected from falls at heights 4 feet (1.2 m) or more above a lower level.
Recent events (2)
  • — C (S) $5064
  • — Z (S) $5064

1910.304 G05

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 4, 2025
Abate by
Sep 16, 2025
Penalty
Initial $10,130 · Current $10,130
29 CFR  1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective.  On or about March 25, 2025; drilling pad; the path to ground from equipment, circuits were not effective and continuous.
Recent events (2)
  • — C (S) $10130
  • — Z (S) $10130

1910.305 G02 III

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 4, 2025
Abate by
Sep 16, 2025
Penalty
Initial $8,442 · Current $8,442
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.   On or about March 25, 2025, trailer area; the crew trailer mini-split power cord did not have a strain relief device that prevented pull from being directly transmitted to joints or terminal screws.
Recent events (2)
  • — C (S) $8442
  • — Z (S) $8442

1910.303 B07 I

Other-than-serious 1 instance 6 exposed
Issued
Sep 4, 2025
Abate by
Sep 16, 2025
Penalty
Initial $948 · Current $948
29 CFR  1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.   On or about March 25, 2025, chemical tank area; unused opening in panel was not effectively closed.
Recent events (2)
  • — C (O) $948
  • — Z (O) $948

View Ranger Energy Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348141011.