Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HIGH'S CHIMNEY SERVICE INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HIGH'S CHIMNEY SERVICE INC. in 4624 VAN NESS NW, WASHINGTON, DC 20013 (NAICS 238140). OSHA activity number 342390465.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch High'S Chimney Service INC. — free Get an email when a new federal OSHA severe-injury report for High'S Chimney Service INC. is published. One employer, no account, unsubscribe in one click.
Site address
4624 VAN NESS NW
City
WASHINGTON
State
DC
ZIP
20013
Mailing
8045 SNOUFFER SCHOOL ROAD, GAITHERSBURG, MD 20879
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
8
Ownership type
A

4 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 1, 2017
Abate by
Sep 12, 2017
Penalty
Initial $4,183 · Current $2,700 Reduced
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights     a) On or about May 30, 2017; side of the residential home; employees. repairing a chimney, were working off a scaffold system in which the working platform was not fully planked exposing them to an estimated 30-foot fall to ground level; missing two planks.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4183

1926.451 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 1, 2017
Abate by
Sep 12, 2017
Penalty
Initial $4,182 · Current $2,700 Reduced
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph.    a) On or about May 30, 2017; side of the residential home; employees were working on a scaffold system with a height to base width of 5:1 that was not restrained from tipping exposing them to a potential 30' fall.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4182

1926.451 G01 VII

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 1, 2017
Abate by
Sep 12, 2017
Penalty
Initial $4,183 · Current $2,700 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.        a) On or about May 30, 2017; scaffold located on the side of the building; employees were working on the working platform of a scaffold system in which the top-rails was not installed exposing employees to a 30-foot fall to ground level.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4183

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 1, 2017
Abate by
Sep 12, 2017
Penalty
Initial $4,182 · Current $2,700 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     a) On or about May 30, 2017; roof area; an employee was working on a roof without proper fall protection exposing him to a potential fall hazard, an estimated 35 feet, while removing the chimney system.        In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4182

View High'S Chimney Service INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342390465.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.