RIDGECREST, CA ·
OSHA Inspection: NAVAL FACILITIES ENGINEERING COMMAND - CHINA LAKE RECURRING MAINTENANCE SHOP
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NAVAL FACILITIES ENGINEERING COMMAND - CHINA LAKE RECURRING MAINTENANCE SHOP in BUILDING 01198, RIDGECREST, CA 93555 (NAICS 928110). OSHA activity number 342413044.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- BUILDING 01198
- City
- RIDGECREST
- State
- CA
- ZIP
- 93555
- Mailing
- 429 EAST BOWEN AVENUE STOP 4007, RIDGECREST, CA 93555
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 8
- Ownership type
- Federal government (D)
Citations
5 citations on file for this inspection.
1910.305 G01 IV A
- Issued
- Dec 5, 2017
- Abate by
- Jan 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Recurring Maintenance Shop: Employees were exposed to electric shock/fire hazards while connecting a Port-A-Cool (Portable Evaporative Cooling Unit), Model PAC2K363S to a flexible cord.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.305 G01 IV B
- Issued
- Dec 5, 2017
- Abate by
- Jan 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: Recurring Maintenance Shop: Employees were exposed to electric shock/fire hazards while connecting a Port-A-Cool (Portable Evaporative Cooling Unit), Model PAC2K363S to a flexible cord which is run through hole in wall to connect to outlet.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.212 A01
- Issued
- Dec 5, 2017
- Abate by
- Jan 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Recurring Maintenance Shop: Employees were exposed to caught in hazards while working on the 14 Inch Lodge and Shipley Lathe, Serial Number COWAN 054628 with an unguarded chuck. (b) Recurring Maintenance Shop: Employees were exposed to caught in hazards while working on the 13 Inch Monarch Machine Tool Company Lathe, Serial Number 37988 with an unguarded chuck. THE U. S. NAVY WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 967513, CITATION 01, ITEM NUMBER 00 AND WAS AFFIRMED AS A FINAL ORDER ON JUNE 25, 2016, WITH RESPECT TO A WORKPLACE LOCATED AT U. S. NAVY, NAVFAC LEMOORE - NAVAL FACILTIES ENGINEERING COMMAND SOUTHWEST REGION, BUILDING 750 ENTERPRISE AVENUE, LEMOORE NAVAL IR STATION, CALIFORNIA 93246.
Recent events (2)
- · I (S) $0
- · Z (R) $0
1910.215 A04
- Issued
- Dec 5, 2017
- Abate by
- Jan 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: Recurring Maintenance Shop: Employees are potentially exposed to impalement hazards when operating the Dayton 10 Inch Bench Grinder, Property Number 6247309352 with the work rest out of adjustment and measured at approximately 7/8th of an inch. THE U. S. NAVY WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 1057074, CITATION 01, ITEM NUMBER 002 AND WAS AFFIRMED AS A FINAL ORDER ON JUNE 05, 2015, WITH RESPECT TO A WORKPLACE LOCATED AT U. S. NAVAL FACILTIES ENGINEERING COMMAND SOUTHWEST, 511 GARDEN ROAD, BUILDING 426, ROOM 011, MONTEREY, CALIFORNIA 93943.
Recent events (2)
- · I (S) $0
- · Z (R) $0
1910.215 B09
- Issued
- Dec 5, 2017
- Abate by
- Jan 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: (a) Recurring Maintenance Shop: Employees are potentially exposed to impalement hazards when operating the Baldor 10 Inch Grinder, Spec Number G10 164 8 with the tongue guard out of adjustment and measured at approximately 5/16th of an inch. (b) Recurring Maintenance Shop: Employees are potentially exposed to impalement hazards when operating the Dayton 10 Inch Bench Grinder, Property Number 6247309352 with the tongue guard out of adjustment and measured at approximately 1/2 of an inch. THE U. S. NAVY WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCUPATIONAL SAFETY AND HEALTH STANDARD, WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 967513, CITATION 01, ITEM NUMBER 003 AND WAS AFFIRMED AS A FINAL ORDER ON JUNE 25, 2016, WITH RESPECT TO A WORKPLACE LOCATED AT U. S. NAVY, NAVFAC LEMOORE - NAVAL FACILTIES ENGINEERING COMMAND SOUTHWEST REGION, BUILDING 750 ENTERPRISE AVENUE, LEMOORE NAVAL IR STATION, CALIFORNIA 93246.
Recent events (2)
- · I (S) $0
- · Z (R) $0
More inspections at Naval Facilities Engineering Command - China Lake Recurring Maintenance Shop
More inspections in this industry (NAICS 928110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342413044.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.