OSHA Inspection: MEDTRONIC, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MEDTRONIC, INC. in 37A CHERRY HILL DRIVE, DANVERS, MA 01923 (NAICS 339112). OSHA activity number 342420890.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Medtronic, INC. — free Get an email when a new federal OSHA severe-injury report for Medtronic, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MEDTRONIC, INC.
Site address
37A CHERRY HILL DRIVE
City
DANVERS
State
MA
ZIP
01923
Mailing
37A CHERRY HILL DRIVE, DANVERS, MA 01923
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339112
Employees
600
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 4 exposed
Issued
Aug 17, 2017
Abate by
Oct 4, 2017
Penalty
Initial $7,470 · Current $3,500 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to rack collapse hazards and overhead struck-by hazards from bent racking and the material stored on them in the following but not limited to area;    Location: Building #35    On or about 6/23/17, employees were exposed to rack collapse hazards and overhead struck by hazards, due to racking upright section M702600B001 and PK90038 being out of plumb by approximately 1-inch.    Abatement language amended to:  Among other methods, feasible and acceptable abatement methods to correct this hazardous condition would include the following elements...(see original citation language)    5a1 abatement element 1 amended to:  1. Inspect and remove all damaged storage racks from service in accordance with ANSI MH16.1:2008, Specification for the Design, Testing, and Utilization of Industrial Steel Storage Racks, Section 1.4.11.1 (out-of-plumb limit) and Section 1.4.11.2 (out-of-straight limit).
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7470

1910.37 A04

Other-than-serious 1 instance 4 exposed
Issued
Aug 17, 2017
Penalty
Initial $6,349 · Current $800 Reduced
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:    Location: Building #35, Rack #2062    On or about 6/23/17, the employer exposed employees to life safety hazards due to not maintaining the minimum 18-inches of clearance between the automatic sprinkler system and the pallet of syringes stored in the warehouse racking below.
Recent events (2)
  • — I (O) $800
  • — Z (S) $6349

View Medtronic, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342420890.