Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of RUDEEN DEVELOPMENT LLC in 4148 E 16TH AVENUE, POST FALLS, ID 83854 (NAICS 236116). OSHA activity number 342426301.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rudeen Development LLC — free Get an email when a new federal OSHA severe-injury report for Rudeen Development LLC is published. One employer, no account, unsubscribe in one click.
Site address
4148 E 16TH AVENUE
City
POST FALLS
State
ID
ZIP
83854
Mailing
695 N LEGACY RIDGE DRIVE SUITE # 301, LIBERTY LAKE, WA 99019
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
24
Ownership type
A

4 citations on file for this inspection.

1926.20 B01

Deleted Serious Gravity 5 1 instance 20 exposed
Issued
Jul 13, 2017
Abate by
Aug 8, 2017
Penalty
Initial $3,622 · Current $0 Reduced
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part.  a)  On or about June 22, 2017, and at times prior thereto, the employer had not developed and/or implemented an accident prevention program to address hazards to which their employees and/or the employees of subcontractors are exposed. Hazards include but are not limited to falls, unguarded decks and/or framing activities at elevated heights without the use of fall protection, fire hazards while employees were observed smoking in the wood structures without fire suppression equipment in place and/or overhead hazards.   Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3622

1926.20 B02

Deleted Serious Gravity 5 1 instance 20 exposed
Issued
Jul 13, 2017
Abate by
Aug 8, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person:   a) On or about June 22, 2017, and at times prior thereto, the employer did not perform effective frequent and regular inspections of sites that they controlled to identify, correct and/or eliminate hazards to which their employees and/or the employees of subcontractors were exposed.  Hazards include but are not limited to falls from working on unguarded decks and/or framing activities at elevated heights without the use of fall protection, fire hazards while employees were observed smoking in the wood structures without fire suppression equipment in place, and/or overhead hazards.   Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B01

Serious 1 instance 20 exposed
Issued
Jul 13, 2017
Abate by
Aug 8, 2017
Penalty
Initial $3,622 · Current $1,811 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:    a) On or about June 22, 2017, the controlling employer, Rudeen Development LLC did not ensure that its sub-contractors protected their employees while they accessed decks without a completed guardrail system was not in place.  Employees were exposed to approximate 10 - 18 foot fall hazards.    Note) Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $1811
  • — Z (S) $3622

1926.150 C01 I

Other-than-serious 1 instance 20 exposed
Issued
Jul 13, 2017
Abate by
Aug 8, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof:  a) On or about June 22, 2017 and at times prior thereto, as the controlling employer, fire extinguishers were not provided in all the buildings under construction.  Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Rudeen Development LLC's full OSHA safety record →