TAMPA, FL —
OSHA Inspection: BIGMECHANIC.COM, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BIGMECHANIC.COM, INC. in 815 E HILLSBOROUGH AVE., TAMPA, FL 33604 (NAICS 811111). OSHA activity number 342427267.
Where did this inspection happen?
- Establishment
- BIGMECHANIC.COM, INC.
- Site address
- 815 E HILLSBOROUGH AVE.
- City
- TAMPA
- State
- FL
- ZIP
- 33604
- Mailing
- P.O. BOX 1136, DADE CITY, FL 33526
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $5070.00 · Current $5070.00
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential crushing hazards from hydraulic lifts: a) For the hydraulic lifts used on site, as observed on or about 06/27/2017, safety stops failed to deploy as the lift was in raised positions exposing employees to potential crushing hazards.
Recent events (1)
- — Z (S) $5070
1910.253 B02 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: a) For the shop location, as observed on or about 06/27/2017, an acetylene cylinder in storage was missing a valve cap.
Recent events (1)
- — Z (O) $0
1910.253 B04 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) For the auto shop, as observed on or about 06/27/2017, acetylene cylinders were stored directly adjacent to oxygen cylinders.
Recent events (2)
- — Z $700
- — Z (O) $0
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) For the shop, as observed on or about 06/27/2017, a yellow extension cord was ripped and spliced with electrical tape. This condition does not comply the cord's original design/listing and labeling. b) For the shop, as observed on or about 06/27/2017, the power cord for a chop saw was spliced into another power cord and taped together. This condition does not comply with the equipment's original design/listing or labeling.
Recent events (1)
- — Z (O) $0
1910.305 B01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions: a) For the conduit used to power hydraulic lifts, as observed on or about 06/27/2017, conduit was cracked at the entrance point to fittings resulting in the potential for the abrasion of interior wiring.
Recent events (1)
- — Z (O) $0
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: For the auto shop, as observed on or about 06/27/2017, the following strain relief hazards were present: a) The power cord for the pipe bender had no strain relief at its plug resulting in strain being placed on the inner conductors. b) A red extension cord had insulation revoved at its plug resulting in a lack of strain relief
Recent events (1)
- — Z (O) $0
More inspections at BIGMECHANIC.COM, INC.
TAMPA, FL—2018-03-08 00:00:00
BIGMECHANIC.COM, INC.
TAMPA, FL—2018-03-08 00:00:00
BIGMECHANIC.COM, INC.
TAMPA, FL—2017-06-28 00:00:00
BIGMECHANIC.COM, INC.
TAMPA, FL—2013-08-07 00:00:00
BIGMECHANIC.COM, INC
TAMPA, FL—2013-04-09 00:00:00
BIGMECHANIC.COM, INC.
View BIGMECHANIC.COM, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811111)
SHERIDAN, CO—2026-07-15 00:00:00
JOHN'S COLLISION REPAIR, INC.
MANASSAS, VA—2026-07-15 00:00:00
VAFMC LLC
NORFOLK, VA—2026-07-15 00:00:00
CITY OF NORFOLK DEPT OF GENERAL SERVICES DIVISION OF FLEET MANAGEMENT
ENOLA, PA—2026-07-15 00:00:00
ENOLA AUTO SALES
LYNCHBURG, TN—2026-07-14 00:00:00
MOORE COUNTY SCHOOLS - BUS GARAGE
More inspections in FL
DELAND, FL—2026-07-16 00:00:00
BALL FABRICS
GAINESVILLE, FL—2026-07-16 00:00:00
WACKY SAUCES LLC
FORT WALTON BEACH, FL—2026-07-16 00:00:00
WASTE MANAGEMENT, INC. OF FLORIDA
PONCE INLET, FL—2026-07-16 00:00:00
RESOLUTE ROOFING LLC
PALM COAST, FL—2026-07-16 00:00:00
J & J TREE EXPERTS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342427267.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.