AIRWAY HEIGHTS, WA —
OSHA Inspection: NORTHERN QUEST RESORT AND CASINO
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of NORTHERN QUEST RESORT AND CASINO in 100 NORTH HAYFORD RD, AIRWAY HEIGHTS, WA 99001 (NAICS 721120). OSHA activity number 342442241.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NORTHERN QUEST RESORT AND CASINO
- Site address
- 100 NORTH HAYFORD RD
- City
- AIRWAY HEIGHTS
- State
- WA
- ZIP
- 99001
- Mailing
- 100 NORTH HAYFORD RD, AIRWAY HEIGHTS, WA 99001
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721120
- Employees
- 1700
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.101 B
- Issued
- Nov 2, 2017
- Abate by
- Nov 30, 2017
- Penalty
- Initial $5,432 · Current $2,716 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: A) In the Welding shop there was a gas cylinder that was not properly secured to keep from falling over.
Recent events (2)
- — I (S) $2716
- — Z (S) $5432
1910.212 A03 II
- Issued
- Nov 2, 2017
- Abate by
- Dec 21, 2017
- Penalty
- Initial $7,243 · Current $3,622 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): A) In the metal shop, there was a horizontal band saw that did not have a guard over the portion of the blade that was not in contact with the material being cut.
Recent events (2)
- — I (S) $3621.5
- — Z (S) $7243
1910.212 B
- Issued
- Nov 2, 2017
- Abate by
- Dec 21, 2017
- Penalty
- Initial $5,432 · Current $2,716 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: A) In the welding shop, and the woodworking shop there were drill presses that were not secured to the floor.
Recent events (2)
- — I (S) $2716
- — Z (S) $5432
1910.213 B03
- Issued
- Nov 2, 2017
- Abate by
- Dec 21, 2017
- Penalty
- Initial $7,243 · Current $3,622 Reduced
General-duty citation text
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure: A) in the woodworking shop, none of the power tools had means by which to prevent accidental start up after a power failure.
Recent events (2)
- — I (S) $3621.5
- — Z (S) $7243
1910.303 B02
- Issued
- Nov 2, 2017
- Abate by
- Dec 21, 2017
- Penalty
- Initial $5,432 · Current $2,716 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: A) In the woodworking shop, employees had fabricated a floor pendant cord out of a flexible cord, and a standard wall fixture box that was not designed for that kind of purpose.
Recent events (2)
- — I (S) $2716
- — Z (S) $5432
1910.305 B02 I
- Issued
- Nov 2, 2017
- Abate by
- Dec 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: A) In the woodworking shop, there was a pendant cord that did not have a cover for the box in which the outlet was installed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 B
- Issued
- Nov 2, 2017
- Abate by
- Dec 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(b): The employer did not ensure that each walking-working surface can support the maximum intended load for that surface. A) In the maintenance facility, there was a storage loft that did not have its load rating posted.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.151 C
- Issued
- Nov 2, 2017
- Abate by
- Nov 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. A) In the main kitchen of the casino, the employer had installed an eye wash station with wash bottles for employees handling hazardous cleaning chemicals, however the station was missing the wash bottles.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Nov 2, 2017
- Abate by
- Dec 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: A) In the banquet kitchen, there were flexible extension cords installed through the ceiling to power kitchen equipment.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV B
- Issued
- Nov 2, 2017
- Abate by
- Dec 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: A) In the banquet kitchen,flexible extension cords were run through holes in the ceiling.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F05
- Issued
- Nov 2, 2017
- Abate by
- Dec 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: A) In the maintenance building there was a spray bottle filled with yellow liquid that was not labeled as to its contents.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Northern Quest Resort and Casino
View Northern Quest Resort and Casino's full OSHA safety record →
More inspections in this industry (NAICS 721120)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342442241.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.