MILWAUKEE, WI —
OSHA Inspection: SELLARS ABSORBENT MATERIALS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SELLARS ABSORBENT MATERIALS, INC. in 6540 NORTH INDUSTRIAL ROAD, MILWAUKEE, WI 53223 (NAICS 322291). OSHA activity number 342443686.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SELLARS ABSORBENT MATERIALS, INC.
- Site address
- 6540 NORTH INDUSTRIAL ROAD
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53223
- Mailing
- 6565 NORTH 60TH STREET, MILWAUKEE, WI 53223
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322291
- Employees
- 38
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A03 II
- Issued
- Nov 24, 2017
- Abate by
- Dec 6, 2017
- Penalty
- Initial $11,408 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Employees were exposed to crushing/nip point hazards and amputation injury while working on and around the Printer #1 of the DCR Line. The employer did not ensure the point of operation was properly guarded. (b) Employees were exposed to crushing/nip point hazards and amputation injury while working on and around the Core Pit of the DCR Line. The employer did not ensure the point of operation was properly guarded.
Recent events (2)
- — I (S) $7000
- — Z (S) $11408
1910.303 B02
- Issued
- Nov 24, 2017
- Abate by
- Dec 6, 2017
- Penalty
- Initial $5,541 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Printer #1 of DCR Line: Power electrical strips were not installed and used in accordance with instructions included in the listing, labeling or certification. The power electrical strips were not approved to be used in an industrial and dusty environment.
Recent events (2)
- — I (S) $0
- — Z (S) $5541
More inspections at Sellars Absorbent Materials, INC.
View Sellars Absorbent Materials, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 322291)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342443686.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.