OSHA Inspection: ACCO BRANDS USA LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ACCO BRANDS USA LLC in 949 MAIN STREET, ALEXANDRIA, PA 16611 (NAICS 424120). OSHA activity number 342445582.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Acco Brands USA LLC for free Get an email when a new federal OSHA severe-injury report for Acco Brands USA LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ACCO BRANDS USA LLC
Site address
949 MAIN STREET
City
ALEXANDRIA
State
PA
ZIP
16611
Mailing
949 MAIN STREET, ALEXANDRIA, PA 16611
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424120
Employees
200
Ownership type
Private (A)

1 citation on file for this inspection.

5(a)(1)

Other-than-serious 36 instances 50 exposed
Issued
Aug 25, 2017
Abate by
Jan 1, 2019
Penalty
Initial $8,149 · Current $8,149
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to crushing hazards:    a) Warehouse areas - Sufficient safe clearances did not exist in some floor level storage rack slots where employees operating Raymond, CAT, Crown and Jun standup rider forklifts in that the operator compartment and overhead guard of this forklift had heights above the floor of 50 inches and a height of 82.5 inches respectively; while the horizontal rack beams located throughout the storage racks were at a height of 70.5 inches from the floor to the bottom of the beam. This would allow the horizontal rack beam at some storage locations to enter the operator compartment of the Raymond, CAT, Crown and Jun standup style forklift, pinning the operator between the horizontal rack beam and the frame of the forklift, on or about July 5, 2017    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (3)
  • · F (O) $8149
  • · C (S) $8149
  • · Z (S) $8149

View Acco Brands USA LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342445582.