MCDONOUGH, GA —
OSHA Inspection: STRUCTURAL SUBCONTRACTORS SERVICE, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of STRUCTURAL SUBCONTRACTORS SERVICE, LLC in 325 SOUTH POINT BLVD., MCDONOUGH, GA 30253 (NAICS 238130). OSHA activity number 342454949.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STRUCTURAL SUBCONTRACTORS SERVICE, LLC
- Site address
- 325 SOUTH POINT BLVD.
- City
- MCDONOUGH
- State
- GA
- ZIP
- 30253
- Mailing
- 4106 SOMERSET RIDGE, BIRMINGHAM, AL 35242
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 32
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B01
- Issued
- Oct 12, 2017
- Abate by
- Nov 7, 2017
- Penalty
- Initial $5,070 · Current $5,070
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. On or about July 7, 2017, an employee was exposed to fall hazards of approximately nine feet when the employee cleaned wood from a balcony without fall protection. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
- — A (S) $5070
- — I (S) $2535
- — Z (S) $5070
1926.503 A02
- Issued
- Oct 12, 2017
- Abate by
- Nov 7, 2017
- Penalty
- Initial $8,874 · Current $8,874
General-duty citation text
29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii) On or about July 7, 2017, employees were exposed to fall hazards when the employees had not been trained on the following: a. fall protection is required whether a person is working near the edge of a low slope roof or in the center of a low slope roof b. fall protection is required when moving material c. fall protection is required and additional equipment must be procured when there are not enough ropes d. fall protection is required and appropriate equipment must be procured when the ropes are not long enough e. fall protection is required when working at six feet or more above the lower surface In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
- — A (S) $8874
- — I (S) $4437
- — Z (S) $8874
1926.501 B13
- Issued
- Oct 12, 2017
- Abate by
- Nov 7, 2017
- Penalty
- Initial $88,725 · Current $88,725
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: On or about July 7, 2017, employees were exposed to fall hazards of approximately 19 feet and greater when employees were working on an apartment roof. The employees were wearing harnesses but had not attached a rope or lanyard to their harnesses. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
- — A (W) $88725
- — I (W) $44362.5
- — Z (W) $88725
More inspections at Structural Subcontractors Service, LLC
View Structural Subcontractors Service, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342454949.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.