Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JOSE DANIEL TACURI

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JOSE DANIEL TACURI in 8 WEST MAIN ST, SPENCER, MA 01562 (NAICS 238160). OSHA activity number 342467131.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jose Daniel Tacuri — free Get an email when a new federal OSHA severe-injury report for Jose Daniel Tacuri is published. One employer, no account, unsubscribe in one click.
Establishment
JOSE DANIEL TACURI
Site address
8 WEST MAIN ST
City
SPENCER
State
MA
ZIP
01562
Mailing
34 CONGRESS ST APT 2, MILFORD, MA 01757
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

6 citations on file for this inspection.

1903.19 C03

Other-than-serious 4 instances 4 exposed
Issued
Oct 18, 2017
Abate by
Oct 30, 2017
Penalty
Initial $305 · Current $305
29 CFR 1903.19(c)(3): The employer did not certify to OSHA within 10 calendar days after the abatement date, that each cited violation had been abated:  As of October 17, 2017, the employer had not certified to OSHA that the abatement was completed for the following violations;   Citation 1, Item 1, Item 2, Item 3a and  Item 3b   from Inspection 1246713, issued on 7/24/17 with a final order date of 9/13/2017
Recent events (1)
  • — Z (O) $305

1903.19 D01

Other-than-serious 4 instances 10 exposed
Issued
Oct 18, 2017
Abate by
Oct 30, 2017
Penalty
Initial $305 · Current $305
29 CFR 1903.19(d)(1): The employer did not  submit to the Agency,  documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required:   As of October 17, 2017, the employer had not submitted documents to the Agency  that the abatement was completed for the following violations;   Citation 1, Item 1, Item 2, Item 3a and  Item 3b   from Inspection 1246713, issued on 7/24/17 with a final order date of 9/13/2017
Recent events (1)
  • — Z (O) $305

1926.150 C01 VI

Serious Gravity 5 1 instance 6 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $2,988 · Current $2,988
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite.  a) 8 West Main St., Spencer, MA: On or about May 1, 2017, two  full (2) 5 gallon gas containers were in use at this worksite without any fire extinguisher present.  Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (1)
  • — Z (S) $2988

1926.501 B13

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $4,183 · Current $4,183
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system.  a) 8 West Main St., Spencer, MA: On or about May 1, 2017, several employees were observed roofing this residence without any fall protection, more than 17 feet above the ground below.   Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (1)
  • — Z (S) $4183

1926.1053 B01

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $4,183 · Current $4,183
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access.  a) 8 West Main St., Spencer, MA: On or about May 1, 2017, several employees were observed using an aluminum extension ladder to access the upper landing surface that did not extend 3 feet past that surface.   Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (1)
  • — Z (S) $4183

1926.1053 B12

Serious Gravity 10 1 instance 6 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(12): Ladders did not have nonconductive siderails when they were used where the employee or the ladder could contact exposed energized electrical equipment.  a) 8 West Main St., Spencer, MA: On or about May 1, 2017, several employees were observed using an aluminum extension ladder to access the upper landing surface which was immediately adjacent to the energized house electrical service cable.   Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (1)
  • — Z (S) $0

View Jose Daniel Tacuri's full OSHA safety record →