Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BAKER DC, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BAKER DC, LLC in 800 10TH STREET NW, WASHINGTON, DC 20004 (NAICS 238110). OSHA activity number 342483476.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Baker DC, LLC — free Get an email when a new federal OSHA severe-injury report for Baker DC, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
BAKER DC, LLC
Site address
800 10TH STREET NW
City
WASHINGTON
State
DC
ZIP
20004
Mailing
1000 POTOMAC STREET NW, SUITE 106, WASHINGTON, DC 20007
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
800
Ownership type
A

1 citation on file for this inspection.

1926.703 A01

Other-than-serious 1 instance 2 exposed
Issued
Sep 29, 2017
Abate by
Oct 10, 2017
Penalty
Initial $11,408 · Current $11,408
29 CFR 1926.703(a)(1): Formwork was not designed, fabricated, erected, supported, braced and maintained so that it would be capable of supporting without failure all vertical and lateral loads that could reasonably be anticipated to be applied to the form    a) On or about June 30, 2017; second floor area of construction; the employer had not ensured that the forms used in the process were properly secured/braced to prevent them from displacing and exposing employees to a 16 foot fall to the concrete floor. The form was braced in place by three (3x) legs, around the columns which were not secured at the top or lower levels.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • — F (O) $11408
  • — C (S) $11408
  • — Z (S) $11408

View Baker DC, LLC's full OSHA safety record →