Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INTERNATIONAL CORDAGE EAST, LTD.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of INTERNATIONAL CORDAGE EAST, LTD. in 555 NORWICH AVENUE, TAFTVILLE, CT 06380 (NAICS 314991). OSHA activity number 342494150.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch International Cordage East, LTD. — free Get an email when a new federal OSHA severe-injury report for International Cordage East, LTD. is published. One employer, no account, unsubscribe in one click.
Site address
555 NORWICH AVENUE
City
TAFTVILLE
State
CT
ZIP
06380
Mailing
226 UPTON ROAD, COLCHESTER, CT 06415
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
314991
Employees
110
Ownership type
A

6 citations on file for this inspection.

1910.25 B01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Oct 10, 2017
Penalty
Initial $4,710 · Current $0 Reduced
29 CFR 1910.25(b)(1): (1) Handrails, stair rail systems, and guardrail systems are provided in accordance with 29 CFR 1910.28:  Entrance Stairs:  On, or about, July 25, 2017, the railing provided on the main entrance stairs was measured to be 30 inches high.   Ref. 29  CFR 1910.29(b)(1)
Recent events (2)
  • — I (S) $0
  • — Z (S) $4710

1910.36 B02

Other-than-serious 1 instance 3 exposed
Issued
Oct 10, 2017
Penalty
Initial $4,710 · Current $0 Reduced
29 CFR 1910.36(b)(2): More than two exit routes were not available in the workplace where the number of employees, the size of the building, its occupancy, or the arrangement of the workplace was such that all employees would not be able to evacuate safely during an emergency:    Warehouse:   On, or about, July 25, 2017, the warehouse space that was located beyond the exit door to the front exit stairwell exceeded the length of travel for a dead-end corridor/common path of travel as defined by National Fire Protection Association (NFPA) Standard 101 Life Safety Code.  The length of the space exceeded 100 feet and was not provided with a secondary exit.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4710

1910.37 A03

Other-than-serious 1 instance 3 exposed
Issued
Oct 10, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level:    Warehouse:  On, or about, July 25, 2017, the exit doors provided to exit into the front stairwell were secured shut with a board.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 10, 2017
Abate by
Nov 28, 2017
Penalty
Initial $4,155 · Current $3,000 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:      Warehouse Desk:  On, or about, July 25, 2017, a relocatable power tap was used to energize computer equipment.  It was energized through an extension cord that is not an appropriate use in accordance with usage instructions  contained in the UL Whitebook.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4155

1910.305 G01 IV A

Serious Gravity 1 1 instance 3 exposed
Issued
Oct 10, 2017
Abate by
Nov 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  Warehouse Desk:  On, or about, July 25, 2017, an orange extension cord was used in lieu of permanent wiring to provide power to  a relocatable power tap used at the workdesk.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07

Other-than-serious 1 instance 3 exposed
Issued
Oct 10, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7): Electric equipment was not installed in a neat and workmanlike manner:  Warehouse located at 555 Norwich Avenue, Taftville, Connecticut:  On, or about, July 25, 2017, service cable that was used to energize the Siemens circuit breaker box located near the entrance door was run along the ceiling attached to plumbing J hooks with plastic ties.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View International Cordage East, LTD.'s full OSHA safety record →