Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U S ELECTRICAL SERVICES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of U S ELECTRICAL SERVICES, INC. in 2050 MOUNTAIN INDUSTRIAL BLVD, TUCKER, GA 30084 (NAICS 493110). OSHA activity number 342496734.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U S Electrical Services, INC. — free Get an email when a new federal OSHA severe-injury report for U S Electrical Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2050 MOUNTAIN INDUSTRIAL BLVD
City
TUCKER
State
GA
ZIP
30084
Mailing
2050 MOUNTAIN INDUSTRIAL BLVD, TUCKER, GA 30084
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
37
Ownership type
A

9 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 3 exposed
Issued
Jan 12, 2018
Abate by
Feb 8, 2018
Penalty
Initial $5,691 · Current $3,984 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees  On or about July 25, 2017, employees were exposed to struck-by hazards when damaged racks had not been unloaded, repaired or replaced.  Employees drive powered industrial trucks, walk, and work in the area. a. bent support leg at location B020101 (ladders are leaning against the end of the rack) b. bent support leg at location A011001 (ladders are leaning against the end of the rack)  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $3983.7
  • — Z (S) $5691

1910.22 D01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jan 12, 2018
Abate by
Feb 8, 2018
Penalty
Initial $5,691 · Current $0 Reduced
29 CFR 1910.22(d)(1): The employer did not ensure that walking-working surfaces were inspected, regularly and as necessary, and maintained in a safe condition:  On or about July 25, 2017, employees were exposed to struck-by hazards when the warehouse racks were not inspected on a regular basis to insure that racks that were damaged were found, emptied, repaired, and/or replaced.  Employees walk and drive powered industrial trucks in the warehouse.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $5691

1910.133 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 12, 2018
Abate by
Feb 8, 2018
Penalty
Initial $7,114 · Current $4,980 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  On or about July 25, 2017, employees were not using eye/face protection when changing the propane tanks on the powered industrial trucks.  Employees only used gloves as personal protective equipment.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $4979.8
  • — Z (S) $7114

1910.178 Q07

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 12, 2018
Penalty
Initial $5,691 · Current $3,984 Reduced
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:  On or about July 25, 2017, employees were exposed to struck-by hazards when the employer did not require daily inspections on each shift on each powered industrial truck before it was used on the shift.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $3983.7
  • — Z (S) $5691

1910.178 L06

Repeat 1 instance 3 exposed
Issued
Jan 12, 2018
Penalty
Initial $284 · Current $199 Reduced
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l) or insure that the certification included the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation:  On or about July 25, 2017, employees were exposed to struck-by hazards when the employer had not maintained the documentation required to insure that only authorized employees were driving the forklifts and other powered industrial trucks at the site.  There was no documentation for employees hired in the last 4-7 months who were authorized employees.  No abatement certification or documentation is required for this item.    The employer was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1014894, citation number 1, item number 3 and was affirmed as a final order on 03/17/2015, with respect to a workplace located at 705 Middle Street, Middletown, CT 06457.
Recent events (2)
  • — I (R) $198.8
  • — Z (R) $284

1910.37 B04

Other-than-serious 1 instance 3 exposed
Issued
Jan 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent  On or about July 25, 2017, employees were exposed to fire hazards when the exit sign was legible when in front of it but not when standing/working near the doors to the counter room.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E02

Other-than-serious 1 instance 3 exposed
Issued
Jan 12, 2018
Abate by
Feb 8, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  On or about July 25, 2017, employees were exposed to fire hazards when there had been no monthly checks to insure that the fire extinguishers were not discharged, missing, damaged, improperly hung, and /or unmarked.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G01

Other-than-serious 1 instance 3 exposed
Issued
Jan 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  On or about July 25, 2017, there was no Safety Data Sheet for propane which is the fuel for some of the powered industrial trucks.   No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 3 exposed
Issued
Jan 12, 2018
Abate by
Feb 8, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  On or about July 25, 2017, employees did not know that propane can cause frostbite, burn, or explode.  Employees did not know where to find Safety Data Sheets.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View U S Electrical Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342496734.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.