Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BUFFALO FELT PRODUCTS CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BUFFALO FELT PRODUCTS CORP. in 14 RANSIER DRIVE, WEST SENECA, NY 14224 (NAICS 313230). OSHA activity number 342500931.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Buffalo Felt Products Corp. — free Get an email when a new federal OSHA severe-injury report for Buffalo Felt Products Corp. is published. One employer, no account, unsubscribe in one click.
Site address
14 RANSIER DRIVE
City
WEST SENECA
State
NY
ZIP
14224
Mailing
14 RANSIER DRIVE, WEST SENECA, NY 14224
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313230
Employees
25
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 16, 2017
Abate by
Sep 8, 2017
Penalty
Initial $3,622 · Current $2,600 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by unguarded cutting equipment:    a)  On or about 08/03/2017 in the production area; where employees were exposed to the improperly guarded, non-working portion of the bandknife, while cutting felt squares.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2600
  • — Z (S) $3622

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 16, 2017
Abate by
Sep 8, 2017
Penalty
Initial $2,173 · Current $1,000 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) On or about 08/03/2017 in the adhesive area; where relocatable power taps were used to power portable electric fans used to provide cooling for felt products.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2173

1910.305 G01 IV A

Other-than-serious 1 instance 2 exposed
Issued
Aug 16, 2017
Abate by
Sep 8, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F)      (A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) On or about 08/03/2017 in the cutting area; where an extension cord was used as a replacement for fixed wiring to power pedestal fans.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Buffalo Felt Products Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342500931.