Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,473Inspections Most recent open 2026-07-28 Last loaded 2026-07-31

OSHA Inspection: DEPT OF AGRICULTURE - NRCS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEPT OF AGRICULTURE - NRCS in 2519 SOUTHWEST AVE., HARLAN, IA 51537 (NAICS 924110). OSHA activity number 342503604.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dept of Agriculture - Nrcs — free Get an email when a new federal OSHA severe-injury report for Dept of Agriculture - Nrcs is published. One employer, no account, unsubscribe in one click.
Site address
2519 SOUTHWEST AVE.
City
HARLAN
State
IA
ZIP
51537
Mailing
2519 SOUTHWEST AVE., HARLAN, IA 51537
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924110
Employees
5
Ownership type
D

6 citations on file for this inspection.

1910.303 B02

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 24, 2017
Abate by
Sep 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   Relocatable Power Taps (RPTs) are listed and labeled for low ampere loads:    In the break room a General Electric Model 94041 RPT was used to supply power to high ampere load coffee pots.
Recent events (1)
  • — Z (S) $0

1910.304 G05

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 24, 2017
Abate by
Sep 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  (a) The grounding pin was missing from the electrical plug of the Panasonic pencil sharpener breaking the path to ground.
Recent events (1)
  • — Z (S) $0

1910.157 E03

Repeat Gravity 5 2 instances 5 exposed
Issued
Aug 24, 2017
Abate by
Sep 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3) as required by 29 CFR 1960.8(b): Portable fire extinguisher(s) were not subjected to an annual maintenance check:  The Kiddie Dry Chemical Fire extinguisher No. BK-275935 located in the Chevrolet Colorado, license A351828, had not been subjected to an annual maintenance check.  No inspection tags or records were present.  The fire extinguisher No. J-341165 located in the Dodge Dakota, license A349968 had not been subjected to an annual maintenance check.  No inspection tags or records were present.  The USDA-NRCS was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.157(e)(3) which was contained in OSHA inspection number 1182315, Notice number 1, Item 2 and was affirmed as a final order on 11/17/2016  with respect to a workplace located at 1918 Greene St.,  Adel, IA 50003.   The USDA-NRCS was previously cited for a violation of this occupational safety and health standard or its  equivalent standard 29 CFR 1910.157(e)(3) which was contained in OSHA inspection number 1155846, Notice number 1, Item 1 and was affirmed as a final order on 9/1/2016  with respect to a workplace located at 900 4th Ave. Ste., 1, Audobon, IA  50025.
Recent events (1)
  • — Z (R) $0

1910.303 B01

Repeat Gravity 5 1 instance 5 exposed
Issued
Aug 24, 2017
Abate by
Sep 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  In the Kitchenette/break room, a receptacle outlet was not provided with ground-fault circuit-interrupter (GFCI) protection for personnel when the outlet was located within approximately four feet of a sink, exposing employees to an electrical hazard.   One feasible Means of Abatement: Install a GFCI to replace the standard outlet or series connect the outlet to the GFCI on the opposite side of the sink in accordance with NFPA 70 - National Electric Code, Article 210.8(B)(5).   The Department of Agriculture-NRCS was previously cited for a violation of this occupational safety and health standard or similar standard 29 CFR 1910.303(b)(1), which was contained in OSHA inspection number 1217889 Notice number 1, Item 1 and was affirmed as a final order on 6/6/2017 with respect to a workplace located at 904 E. Taylor Street Creston, IA 50801.
Recent events (1)
  • — Z (R) $0

1910.304 B04 II B

Repeat Gravity 5 2 instances 5 exposed
Issued
Aug 24, 2017
Abate by
Sep 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle supplied a total cord- and plug-connected load in excess of the maximum specified in Table S-4:  (a) In the kitchenette/break area, a model 94041 General Electric 15 amp relocatable power tap was furnishing power to two Black and Decker Power coffee pots, exceeding the allowable safe loading capacity of the RPT and receptacle.  The Dept. of Agriculture NRCS was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1215695, Notice number 2, item number 1, with respect to a workplace located in Iowa Falls, IA and became a final order on June 15, 2017.  The Dept. of Agriculture NRCS was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 948245, Notice number 1, item number 2, with respect to a workplace located in Newton, IA and became a final order on January 29, 2014.  Abatement certification and abatement documentation is required for this violation.  The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos, which you believe will be helpful.  The abatement certification sheet is enclosed with the notice(s).
Recent events (1)
  • — Z (R) $0

1910.305 B02 I

Repeat Gravity 5 1 instance 5 exposed
Issued
Aug 24, 2017
Abate by
Sep 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i):  Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    (a) In the NRCS Office, south wall, near the small break area, an outlet did not have a faceplate to protect employees from exposed wiring contacts and damage from insects or rodents entering the box creating a fire hazard.   The USDA-NRCS was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(b)(2)(i) which was contained in OSHA inspection number 1182315, Notice number 1, Item 2 and was affirmed as a final order on 11/17/2016  with respect to a workplace located at 1918 Greene St.,  Adel, IA 50003.  The USDA-NRCS was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(b)(2)(i) which was contained in OSHA inspection number 1219598, Notice number 1, Item 1 and was affirmed as a final order on 5/25/2017 with respect to a workplace located at 605 East State, Algona, IA  50511.
Recent events (1)
  • — Z (R) $0

View Dept of Agriculture - Nrcs's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342503604.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.