RUSSELL SPRINGS, KS —
OSHA Inspection: WW DRILLING LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WW DRILLING LLC in S2,SW, SEC24, TWP15S. R36 WEST., RUSSELL SPRINGS, KS 67764 (NAICS 213111). OSHA activity number 342505740.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WW DRILLING LLC
- Site address
- S2,SW, SEC24, TWP15S. R36 WEST.
- City
- RUSSELL SPRINGS
- State
- KS
- ZIP
- 67764
- Mailing
- PO BOX 307 233 S 4TH ST,, WAKEENEY, KS 67672
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.219 D01
- Issued
- Aug 22, 2017
- Abate by
- Sep 11, 2017
- Penalty
- Initial $4,889 · Current $2,933 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section: Employees engaged in drilling operations were exposed to amputation hazards in that pulleys were not guarded while employees were in the area or working on the generators; a) Main generator b) Premix generator
Recent events (2)
- — I (S) $2933.4
- — Z (S) $4889
1910.219 E01 I
- Issued
- Aug 22, 2017
- Abate by
- Sep 11, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts were seven (7) feet or less from floor level the guard did not extend to at least fifteen (15) inches above the belt or to a standard height: Employees engaged in drilling operations were exposed to amputation hazards in that pulleys were not guarded while employees were in the area or working on the generators; a) Main generator b) Premix generator
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at WW Drilling LLC
View WW Drilling LLC's full OSHA safety record →
More inspections in this industry (NAICS 213111)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342505740.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.