Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WW DRILLING LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WW DRILLING LLC in S2,SW, SEC24, TWP15S. R36 WEST., RUSSELL SPRINGS, KS 67764 (NAICS 213111). OSHA activity number 342505740.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch WW Drilling LLC — free Get an email when a new federal OSHA severe-injury report for WW Drilling LLC is published. One employer, no account, unsubscribe in one click.
Establishment
WW DRILLING LLC
Site address
S2,SW, SEC24, TWP15S. R36 WEST.
City
RUSSELL SPRINGS
State
KS
ZIP
67764
Mailing
PO BOX 307 233 S 4TH ST,, WAKEENEY, KS 67672
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
12
Ownership type
A

2 citations on file for this inspection.

1910.219 D01

Serious Gravity 1 1 instance 12 exposed
Issued
Aug 22, 2017
Abate by
Sep 11, 2017
Penalty
Initial $4,889 · Current $2,933 Reduced
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section:  Employees engaged in drilling operations were exposed to amputation hazards in that pulleys were not guarded while employees were in the area or working on the generators;  a) Main generator  b) Premix generator
Recent events (2)
  • — I (S) $2933.4
  • — Z (S) $4889

1910.219 E01 I

Serious Gravity 1 1 instance 12 exposed
Issued
Aug 22, 2017
Abate by
Sep 11, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts were seven (7) feet or less from floor level the guard did not extend to at least fifteen (15) inches above the belt or to a standard height:   Employees engaged in drilling operations were exposed to amputation hazards in that pulleys were not guarded while employees were in the area or working on the generators;  a) Main generator  b) Premix generator
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View WW Drilling LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342505740.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.