On , OSHA opened a planned safety inspection of HAITIAN CONSTRUCTION GROUP (CNMI) CORPORATION in IMPERIAL PACIFIC RESORT HOTEL SAIPAN, SAIPAN, MP 96950 (NAICS 236220). OSHA activity number 342534831.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HAITIAN CONSTRUCTION GROUP (CNMI) CORPORATION
- Site address
- IMPERIAL PACIFIC RESORT HOTEL SAIPAN
- City
- SAIPAN
- State
- MP
- ZIP
- 96950
- Mailing
- PMB 548 P.O. BOX 10002, SAIPAN, MP 96950
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 118
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.25 A
- Issued
- Jan 3, 2018
- Abate by
- Jan 11, 2018
- Penalty
- Initial $4,155 · Current $2,480 Reduced
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, were not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures. At the loading dock area, lumber with nails sticking out and other debris was in the walkway. Employees were exposed to puncture tripping hazards.
Recent events (3)
- — F (S) $2480
- — C (S) $4155
- — Z (S) $4155
1926.701 B
- Issued
- Jan 3, 2018
- Abate by
- Jan 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.701(b): Protruding reinforcing steel, onto and into which employees could fall was not guarded to eliminate the hazard of impalement. Outside the hotel near the walkways, reinforcing steel rebar was not covered. Employees were exposed to impalement hazards.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.350 A10
- Issued
- Jan 3, 2018
- Abate by
- Jan 11, 2018
- Penalty
- Initial $4,155 · Current $2,480 Reduced
General-duty citation text
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinder or combustible materials, a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour. Next to the blue shipping container, unsecured oxygen and acetylene gas cylinders were stored together. Employees were exposed to fire and struck-by hazards.
Recent events (3)
- — F (S) $2480
- — C (S) $4155
- — Z (S) $4155
1926.350 A11
- Issued
- Jan 3, 2018
- Abate by
- Jan 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.350(a)(11): Cylinders were not stored in definitely assigned storage places where the cylinders would not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Next to the blue shipping container, oxygen and acetylene gas cylinders were not secured to prevent from being knocked over. Employees were exposed to struck-by hazards.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Jan 3, 2018
- Penalty
- Initial $5,541 · Current $2,480 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. At the construction site, employees were observed walking near an unprotected edge that was about 8 feet above the ground. Employees were exposed to fall hazards.
Recent events (3)
- — F (S) $2480
- — C (S) $5541
- — Z (S) $5541
1926.405 G02 IV
- Issued
- Jan 3, 2018
- Abate by
- Jan 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws. At the temporary power panel, flexible cords with the plugs separating from the outer insulation were powering electrical equipment. Employees were exposed to electrical and fire hazards.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1926.416 E01
- Issued
- Jan 3, 2018
- Abate by
- Jan 11, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used. Outside the hotel, a flexible cord with torn outer insulation was used to power a pipe cutter. Employees were exposed to electrical and fire hazards.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Haitian Construction Group (Cnmi) Corporation
View Haitian Construction Group (Cnmi) Corporation's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in MP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342534831.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.