Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: C2 IMAGING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C2 IMAGING, LLC in 1400 W. DARTMOUTH AVE, ENGLEWOOD, CO 80110 (NAICS 323111). OSHA activity number 342535747.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C2 Imaging, LLC for free Get an email when a new federal OSHA severe-injury report for C2 Imaging, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
C2 IMAGING, LLC
Site address
1400 W. DARTMOUTH AVE
City
ENGLEWOOD
State
CO
ZIP
80110
Mailing
1400 W. DARTMOUTH AVE, ENGLEWOOD, CO 80110
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
75
Ownership type
Private (A)

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 3 instances 25 exposed
Issued
Sep 26, 2017
Abate by
Oct 16, 2017
Penalty
Initial $5,541 · Current $3,324 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a)  C2 Imaging, LLC:  On or about August 9, 2017, and at times prior, employees were exposed to amputation or laceration hazards due to lack of adequate guarding on the point of operation of the Rosenthal Sheeter Model material cutter.    (b)  C2 Imaging, LLC: On or about August 9, 2017, and at times prior, employees were exposed to crushing hazards due to lack of adequate guarding on moving parts (such as the cam shaft) of the Stimpson 83GW Grommetter.    (c)  C2 Imaging, LLC: On or about August 9, 2017, and at times prior, employees were exposed to in-running nip points due to bypassing a light curtain sensor on the Orca Pro-Tech Laminator.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (S) $3324
  • · Z (S) $5541

1910.147 C01

Other-than-serious 20 instances 35 exposed
Issued
Sep 26, 2017
Abate by
Oct 16, 2017
Penalty
Initial $914 · Current $548 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a) C2 Imaging, LLC: On or about August 9, 2017, and at times prior, the employer did not establish a program consisting of energy control procedures prior to employees performing servicing or maintenance on printing presses, guillotine cutters, laminators, or other automated machinery in the fabrication area.      Abatement Note: Abatement certification and documentation is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (O) $548
  • · Z (O) $914

1910.303 G01

Other-than-serious 1 instance 5 exposed
Issued
Sep 26, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a)  C2 Imaging, LLC: On or about August 9, 2017, and at times prior, sufficient access and working space was not provided and maintained in front of an electrical panel on the second floor next to the sewing machines.  Thirty-six (36) inches of clearance was not maintained in front of the electrical panel due to a pallet of material being stored directly in front of the panel.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View C2 Imaging, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342535747.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.