Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: C2 IMAGING LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of C2 IMAGING LLC in 1400 W. DARTMOUTH AVE, ENGLEWOOD, CO 80110 (NAICS 323111). OSHA activity number 344611314.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C2 Imaging LLC for free Get an email when a new federal OSHA severe-injury report for C2 Imaging LLC is published. One employer, no account, unsubscribe in one click.
Establishment
C2 IMAGING LLC
Site address
1400 W. DARTMOUTH AVE
City
ENGLEWOOD
State
CO
ZIP
80110
Mailing
1400 W. DARTMOUTH AVE, ENGLEWOOD, CO 80110
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
47
Ownership type
Private (A)

5 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 12 exposed
Issued
May 8, 2020
Abate by
May 28, 2020
Penalty
Initial $12,723 · Current $6,361 Reduced
29 CFR 1910.178(l)(1)(i):  The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    (a)  On or about February 6, 2020, and at times prior, C2 Imaging LLC, as exposing and controlling employer, did not ensure its employees and employees from PrimeSource Staffing, LLC, staffing agency, were protected from struck-by and crushing injuries, in that the forklift operator was not trained in the proper operation of the forklift he was assigned to use, and the operator's competency to operate the forklift was not evaluated prior to assignment to use the Yale ERC050RGN36TE084 forklift at the site.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $6361
  • · Z (S) $12723

1910.178 O01

Serious Gravity 5 1 instance 12 exposed
Issued
May 8, 2020
Abate by
May 28, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.178(o)(1):  The employer did not ensure that only stable or safely arranged loads were handled:  (a)  On or about February 6, 2020, and at times prior, C2 Imaging LLC, as exposing and controlling employer, did not ensure its employees and employees from PrimeSource Staffing, LLC, staffing agency, were protected from struck-by and crushing injuries, in that unstable loads on the forklift were not secured before moving them.  Large piles of scrap foam board, which are slick and have air between them because each sheet is placed one at a time, were not secured before the loads were moved.  A pile fell off of the forks near workers.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 G07

Serious Gravity 1 1 instance 2 exposed
Issued
May 8, 2020
Abate by
May 28, 2020
Penalty
Initial $6,361 · Current $3,181 Reduced
29 CFR 1910.178(g)(7): When charging batteries, water was poured into acid:    (a)  On or about February 6, 2020, and at times prior, C2 Imaging LLC, as exposing and controlling employer, did not ensure its employees and employees from PrimeSource Staffing, LLC, staffing agency, were protected from corrosive fumes and burns in that when the batteries of the forklift were checked and serviced, water was poured into the acid.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $3181
  • · Z (S) $6361

1910.304 B04 II B

Serious Gravity 1 1 instance 5 exposed
Issued
May 8, 2020
Abate by
May 28, 2020
Penalty
Initial $6,361 · Current $3,181 Reduced
29 CFR 1910.304(b)(4)(ii)(B):  Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle may not supply a total cord- and plug-connected load in excess of the maximum specified in Table S-4:    (a)  On or about February 6, 2020, and at times prior, C2 Imaging LLC, as exposing and controlling employer, did not ensure that its employees and employees of PrimeSource Staffing, LLC, were protected from fire and electrical hazards from a relocatable power tap (power strip) that was powered by the Zund cutting machine, and had the Tornado Jumbo vacuum cleaner plugged into it.  The relocatable power tap had a max amperage capacity of 15 amperes. The vacuum had an operating amperage of 15 amperes.  Per Table S-4 the maximum load that can be placed on a receptacle with multiple outlets and rated for 15 amperes, is 12 amperes.     Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $3181
  • · Z (S) $6361

1910.305 G02 III

Serious Gravity 1 1 instance 5 exposed
Issued
May 8, 2020
Abate by
May 28, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  (a)  On or about February 6, 2020, and at times prior, C2 Imaging LLC, as exposing and controlling employer, did not ensure that its employees and employees of PrimeSource Staffing, LLC, staffing agency, were protected from shock and fire hazards from the Zund cutting machine's outlet cord that was powering a relocatable power tap (power strip).  The outlet cord's insulation was pulled back from the outlet exposing the energized wires inside and placing any strain on the cord directly on the terminals of the outlet.    Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View C2 Imaging LLC's full OSHA safety record →