AUSTELL, GA —
OSHA Inspection: UNITY SOUTHERN ENVIRONMENTAL, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of UNITY SOUTHERN ENVIRONMENTAL, INC. in 7170 DELTA CIRCLE, AUSTELL, GA 30168 (NAICS 562111). OSHA activity number 342543279.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITY SOUTHERN ENVIRONMENTAL, INC.
- Site address
- 7170 DELTA CIRCLE
- City
- AUSTELL
- State
- GA
- ZIP
- 30168
- Mailing
- 7170 DELTA CIRCLE, AUSTELL, GA 30168
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562111
- Employees
- 8
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 7, 2018
- Penalty
- Initial $12,934 · Current $7,760 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by/crushing injuries from being caught between two Mack roll-off body trucks while towing as the truck towing unexpectedly rolled down an incline while removing a tow strap. (a) Unity Southern Environmental located at 7170 Delta Circle, Austell, GA, Rear side of steel building: On or about 08/10/2017, and at times prior, the employer exposed employees to struck-by hazard, in that the employer failed to ensure safe work practices were followed to prevent employees from being struck-by the roll-off truck or caught between two vehicles.
Recent events (2)
- — I (S) $7760.4
- — Z (S) $12934
1910.28 B08 I
- Issued
- Feb 7, 2018
- Abate by
- May 1, 2018
- Penalty
- Initial $2,217 · Current $1,330 Reduced
General-duty citation text
29 CFR 1910.28(b)(8)(i): Service pits were not guarded or barricaded to prevent falls or unauthorized access: (a) Unity Southern Environmental, Inc. Facility, Garage: On or about 08/11/2017, and at times prior, the employer exposed employees to fall hazards, in that the employer failed to provide a fall protection system, limit access, apply markings, or post caution signs on the service pit which was 54-inches deep.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
1910.37 A03
- Issued
- Feb 7, 2018
- Penalty
- Initial $2,217 · Current $1,330 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: (a) Unity Southern Environmental, Inc., Service garage east side exit: On or about 08/11/2017, and at times prior, the employer exposed employees to entrapment hazards, in that exit doors located in the service garage were obstructed by 50-gallon drums of anti-freeze blocking the exit. (b) Unity Southern Environmental, Inc., Roll-off service and painting garage rear exit: On or about 08/11/2017, and at times prior, the employer exposed employees to entrapment hazards, in that exit doors located in the painting area were obstructed by painting supplies and roll-off rollers.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
1910.253 B02 II
- Issued
- Feb 7, 2018
- Abate by
- May 1, 2018
- Penalty
- Initial $3,326 · Current $1,996 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior: (a) Unity Southern Environmental, Inc., Roll-Off container service bay: On or about 08/11/2017, and at times prior, the employer exposed employees to struck-by hazards, in that oxygen and acetylene cylinders were not secured or placed at least 20 feet from each other.
Recent events (2)
- — I (S) $1995.5
- — Z (S) $3326
1910.253 B02 IV
- Issued
- Feb 7, 2018
- Abate by
- Feb 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: (a) Unity Southern Environmental, Inc., Main service garage: On or about 08/11/2017, and at times prior, the employer exposed employees to fire and struck-by hazards, in that oxygen cylinders were not capped or secured to prevent tanks from being knocked over or struck-by equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Feb 7, 2018
- Abate by
- Feb 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. (a) Unity Southern Environmental, Inc., Roll-off container service garage: On or about 08/11/2017, and at times prior, the employer exposed employees to fire/explosion hazards, in that oxygen and acetylene cylinders were not stored at least 20-ft. from each other, secured or placed in a designated location.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Feb 7, 2018
- Penalty
- Initial $1,663 · Current $998 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Unity Southern Environmental, Inc. service garage, Electrical panel boxes: On or about 08/11/2017, and at times prior, the employer exposed employees to electrical shock hazards, in that electrical panel doors were open, and blanks for the missing circuit breakers were missing which exposed employees to hazards.
Recent events (2)
- — I (S) $997.8
- — Z (S) $1663
1904.39 A01
- Issued
- Feb 7, 2018
- Penalty
- Initial $2,772 · Current $1,663 Reduced
General-duty citation text
29 CFR 1904.39(a)(1): The employer did not report within 8-hours the death of an employee resulting from a work-related incident: (a) Unity Southern Environmental, Inc. Facility: On or about 08/11/2017, and at times prior, the employer din not report to the Area Office of the Occupational Safety & Health Administration within eight hours after a death of any employee from a work-related incident.
Recent events (2)
- — I (O) $1663.3
- — Z (O) $2772
More inspections at Unity Southern Environmental, INC.
View Unity Southern Environmental, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 562111)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342543279.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.