Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITY SOUTHERN ENVIRONMENTAL, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of UNITY SOUTHERN ENVIRONMENTAL, INC. in 7170 DELTA CIRCLE, AUSTELL, GA 30168 (NAICS 562111). OSHA activity number 342543279.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Unity Southern Environmental, INC. — free Get an email when a new federal OSHA severe-injury report for Unity Southern Environmental, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7170 DELTA CIRCLE
City
AUSTELL
State
GA
ZIP
30168
Mailing
7170 DELTA CIRCLE, AUSTELL, GA 30168
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562111
Employees
8
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 7, 2018
Penalty
Initial $12,934 · Current $7,760 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by/crushing injuries from being caught between two Mack roll-off body trucks while towing as the truck towing unexpectedly rolled down an incline while removing a tow strap.     (a) Unity Southern Environmental located at 7170 Delta Circle, Austell, GA, Rear side of steel building: On or about 08/10/2017, and at times prior, the employer exposed employees to struck-by hazard, in that the employer failed to ensure safe work practices were followed to prevent employees from being struck-by the roll-off truck or caught between two vehicles.
Recent events (2)
  • — I (S) $7760.4
  • — Z (S) $12934

1910.28 B08 I

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 7, 2018
Abate by
May 1, 2018
Penalty
Initial $2,217 · Current $1,330 Reduced
29 CFR 1910.28(b)(8)(i): Service pits were not guarded or barricaded to prevent falls or unauthorized access:    (a) Unity Southern Environmental, Inc. Facility, Garage: On or about 08/11/2017, and at times prior, the employer exposed employees to fall hazards, in that the employer failed to provide a fall protection system, limit access, apply markings, or post caution signs on the service pit which was 54-inches deep.
Recent events (2)
  • — I (S) $1330.2
  • — Z (S) $2217

1910.37 A03

Serious Gravity 5 2 instances 2 exposed
Issued
Feb 7, 2018
Penalty
Initial $2,217 · Current $1,330 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    (a) Unity Southern Environmental, Inc., Service garage east side exit: On or about 08/11/2017, and at times prior, the employer exposed employees to entrapment hazards, in that exit doors located in the service garage were obstructed by 50-gallon drums of anti-freeze blocking the exit.    (b) Unity Southern Environmental, Inc., Roll-off service and painting garage rear exit: On or about 08/11/2017, and at times prior, the employer exposed employees to entrapment hazards, in that exit doors located in the painting area were obstructed by painting supplies and roll-off rollers.
Recent events (2)
  • — I (S) $1330.2
  • — Z (S) $2217

1910.253 B02 II

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 7, 2018
Abate by
May 1, 2018
Penalty
Initial $3,326 · Current $1,996 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:    (a) Unity Southern Environmental, Inc., Roll-Off container service bay: On or about 08/11/2017, and at times prior, the employer exposed employees to struck-by hazards, in that oxygen and acetylene cylinders were not secured or placed at least 20 feet from each other.
Recent events (2)
  • — I (S) $1995.5
  • — Z (S) $3326

1910.253 B02 IV

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 7, 2018
Abate by
Feb 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  (a) Unity Southern Environmental, Inc., Main service garage: On or about 08/11/2017, and at times prior, the employer exposed employees to fire and struck-by hazards, in that oxygen cylinders were not capped or secured to prevent tanks from being knocked over or struck-by equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 7, 2018
Abate by
Feb 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  (a) Unity Southern Environmental, Inc., Roll-off container service garage: On or about 08/11/2017, and at times prior, the employer exposed employees to fire/explosion hazards, in that oxygen and acetylene cylinders were not stored at least 20-ft. from each other, secured or placed in a designated location.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 7, 2018
Penalty
Initial $1,663 · Current $998 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) Unity Southern Environmental, Inc. service garage, Electrical panel boxes: On or about 08/11/2017, and at times prior, the employer exposed employees to electrical shock hazards, in that electrical panel doors were open, and blanks for the missing circuit breakers were missing which exposed employees to hazards.
Recent events (2)
  • — I (S) $997.8
  • — Z (S) $1663

1904.39 A01

Other-than-serious 1 instance 1 exposed
Issued
Feb 7, 2018
Penalty
Initial $2,772 · Current $1,663 Reduced
29 CFR 1904.39(a)(1): The employer did not report within 8-hours the death of an employee resulting from a work-related incident:     (a) Unity Southern Environmental, Inc. Facility: On or about 08/11/2017, and at times prior, the employer din not report to the Area Office of the Occupational Safety & Health Administration within eight hours after a death of any employee from a work-related incident.
Recent events (2)
  • — I (O) $1663.3
  • — Z (O) $2772

View Unity Southern Environmental, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342543279.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.