OSHA Inspection: WILLIE J HARSWELL

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WILLIE J HARSWELL in 649 WEST JAMES ST, SAVANNAH, GA 31401 (NAICS 238140). OSHA activity number 342547890.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Willie J Harswell for free Get an email when a new federal OSHA severe-injury report for Willie J Harswell is published. One employer, no account, unsubscribe in one click.
Establishment
WILLIE J HARSWELL
Site address
649 WEST JAMES ST
City
SAVANNAH
State
GA
ZIP
31401
Mailing
537 NEW STREET, SOPERTON, GA 30457
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
12
Ownership type
A

3 citations on file for this inspection.

1926.451 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 5, 2017
Abate by
Sep 22, 2017
Penalty
Initial $6,338 · Current $6,338
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:  a) South side of the building, on or about August 02, 2017, three employees were working from a tubular welded frame scaffold without a ladder or any other means of safe access/egress to reach the upper levels of the scaffold, thus exposing employees up to 12-foot fall hazard.
Recent events (1)
  • · Z (S) $6338

1926.451 G01

Serious Gravity 10 2 instances 5 exposed
Issued
Sep 5, 2017
Abate by
Sep 22, 2017
Penalty
Initial $8,873 · Current $8,873
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  a) West side of the building, on or about August 02, 2017, several employees were working from a tubular welded frame scaffold without guardrails and no other means of fall protection, thus exposing them up to 30-foot fall hazard.
Recent events (1)
  • · Z (S) $8873

1926.452 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 5, 2017
Abate by
Sep 22, 2017
Penalty
Initial $6,338 · Current $6,338
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:  a) South side of the building, on or about August 02, 2017, three employees were working from a tubular welded frame scaffold that was missing cross braces, thus exposing them up to a 12-foot fall hazard.
Recent events (1)
  • · Z (S) $6338

View Willie J Harswell's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342547890.