GADSDEN, AL —
OSHA Inspection: PRINCE METAL STAMPINGS USA, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PRINCE METAL STAMPINGS USA, INC. in 1108 AIRPORT INDUSTRIAL DRIVE, GADSDEN, AL 35904 (NAICS 336370). OSHA activity number 342578739.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRINCE METAL STAMPINGS USA, INC.
- Site address
- 1108 AIRPORT INDUSTRIAL DRIVE
- City
- GADSDEN
- State
- AL
- ZIP
- 35904
- Mailing
- 1108 AIRPORT INDUSTRIAL DRIVE, GADSDEN, AL 35904
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336370
- Employees
- 195
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Sep 14, 2017
- Abate by
- Sep 26, 2017
- Penalty
- Initial $8,312 · Current $4,987 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 08/16/2017 - Plant 2, an employee conducting maintenance and servicing on a Verson 400 ton press was not utilizing the established specific procedure for the machinery while sanding the rollers on the straightener section.
Recent events (2)
- — I (S) $4987.2
- — Z (S) $8312
1910.147 C06 I
- Issued
- Sep 14, 2017
- Abate by
- Nov 15, 2017
- Penalty
- Initial $8,311 · Current $4,987 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 08/23/2017 - Plant 2, procedures for equipment such as, but not limited to, the Verson 400 ton press created on July 07, 2014 had not been inspected annually.
Recent events (2)
- — I (S) $4986.6
- — Z (S) $8311
More inspections at Prince Metal Stampings USA, INC.