OSHA Inspection: DONALDSON COMPANY INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DONALDSON COMPANY INC. in 5200 COYE DRIVE, STEVENS POINT, WI 54481 (NAICS 333413). OSHA activity number 342586963.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Donaldson Company INC. for free Get an email when a new federal OSHA severe-injury report for Donaldson Company INC. is published. One employer, no account, unsubscribe in one click.
Site address
5200 COYE DRIVE
City
STEVENS POINT
State
WI
ZIP
54481
Mailing
5200 COYO DRIVE, STEVENS POINT, WI 54481
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333413
Employees
569
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 C07 I A

Serious Gravity 5 1 instance 10 exposed
Issued
Jan 26, 2018
Penalty
Initial $6,282 · Current $4,397 Reduced
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.    a. On or about August 16, 2017 employees were not trained as Lockout Authorized employees when they engaged in servicing and maintenance on the Prepress in Department 1685.
Recent events (2)
  • · I (S) $4397.4
  • · Z (S) $6282

1910.147 D

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 26, 2018
Penalty
Initial $6,282 · Current $4,397 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedure) was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6):    a. On or about August 16, 2017, an employee was adjusting the hydraulic pressure on the Prepress in Department 1685 to fix operating issues and did not follow the necessary steps to protect employees from kinetic energy.
Recent events (2)