STEVENS POINT, WI ·
OSHA Inspection: DONALDSON COMPANY INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DONALDSON COMPANY INC. in 5200 COYE DRIVE, STEVENS POINT, WI 54481 (NAICS 333413). OSHA activity number 342586963.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DONALDSON COMPANY INC.
- Site address
- 5200 COYE DRIVE
- City
- STEVENS POINT
- State
- WI
- ZIP
- 54481
- Mailing
- 5200 COYO DRIVE, STEVENS POINT, WI 54481
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333413
- Employees
- 569
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C07 I A
- Issued
- Jan 26, 2018
- Penalty
- Initial $6,282 · Current $4,397 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. a. On or about August 16, 2017 employees were not trained as Lockout Authorized employees when they engaged in servicing and maintenance on the Prepress in Department 1685.
Recent events (2)
- · I (S) $4397.4
- · Z (S) $6282
1910.147 D
- Issued
- Jan 26, 2018
- Penalty
- Initial $6,282 · Current $4,397 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedure) was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6): a. On or about August 16, 2017, an employee was adjusting the hydraulic pressure on the Prepress in Department 1685 to fix operating issues and did not follow the necessary steps to protect employees from kinetic energy.
Recent events (2)
- · I (S) $4397.4
- · Z (S) $6282
More inspections at Donaldson Company INC.
View Donaldson Company INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333413)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342586963.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.