YIGO, GU —
OSHA Inspection: ORION CONSTRUCTION CORPORATION GUAM
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ORION CONSTRUCTION CORPORATION GUAM in TOP OF THE ROCK ANDERSEN AFB, YIGO, GU 96929 (NAICS 236220). OSHA activity number 342605532.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ORION CONSTRUCTION CORPORATION GUAM
- Site address
- TOP OF THE ROCK ANDERSEN AFB
- City
- YIGO
- State
- GU
- ZIP
- 96929
- Mailing
- P.O. BOX 24348 GMF, BARRIGADA, GU 96921
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 13
- Ownership type
- A
Citations
10 citations on file for this inspection.
1926.403 I02 I
- Issued
- Dec 5, 2017
- Penalty
- Initial $3,078 · Current $1,539 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. USO Top of the Rock interior area: The cover for the circuit breaker had been removed during painting operations, exposing energized wiring components inside. Employees were exposed to electrical shock hazards.
Recent events (2)
- — I (S) $1539
- — Z (S) $3078
1926.405 B02
- Issued
- Dec 5, 2017
- Penalty
- Initial $2,463 · Current $1,232 Reduced
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: USO Top of the Rock interior area: The 120 volt outlet mounted to the beam was energized and did not have a faceplate affixed. Employees were exposed to electrical shock hazards.
Recent events (2)
- — I (S) $1231.5
- — Z (S) $2463
1926.451 B01
- Issued
- Dec 5, 2017
- Penalty
- Initial $4,346 · Current $2,173 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolding was not fully planked or decked: USO Gazebo Area: Employees were installing shingles on the gazebo from a supported scaffold that was missing planks on the walking and working platforms. Employees were exposed to fall hazards.
Recent events (2)
- — I (S) $2173
- — Z (S) $4346
1926.451 B09
- Issued
- Dec 5, 2017
- Abate by
- Dec 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(9): Wood platforms were covered with an opaque finish so as to obscure the top or bottom surface USO Gazebo Area: Employees were installing shingles on the gazebo from a supported scaffold that had wooden plank(s) covered with a black opaque material. Employees were exposed to fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02
- Issued
- Dec 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: USO Gazebo Area: Employees were installing shingles on the gazebo from a supported scaffold that was resting partially on rubber matting and cardboard, causing instability in the footing. Employees were exposed to fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F03
- Issued
- Dec 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: USO Gazebo Area: Employees were installing shingles on the gazebo from a supported scaffold that had not been inspected for defects by a competent person prior to the work conducted. Employees were exposed to fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 C02
- Issued
- Dec 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: USO Gazebo Area: Employees were installing shingles on the gazebo from a supported scaffold that was missing cross braces between the frames. Employees were exposed to fall hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.51 F03 III
- Issued
- Dec 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.51(f)(3)(iii): Hand soap or similar cleansing agents was not provided. USO Gazebo Area: Hand soap and/or hand sanitizer was not provided for employees using the restroom. Employees were exposed to sanitation hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.51 F03 IV
- Issued
- Dec 5, 2017
- Abate by
- Dec 13, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.51(f)(3)(iv): Individual hand towels or sections thereof, of cloth or paper, air blowers or clean individual sections of continuous cloth toweling, convenient to the lavatories, were not provided. USO Gazebo Area: Hand towels, or an alternative drying method, was not provided for employees after using the restroom. Employees were exposed to sanitation hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 G08
- Issued
- Dec 5, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not ensure that Safety Data Sheets were readily accessible during each work shift to employees when they were in their work area(s): USO Gazebo Area: A copy of the safety data sheet for the CustomBlend Standard Thin-Set Mortar was maintained at the Safety Supervisor's office and not readily accessible to the employees installing tiles in the gazebos. Employees were exposed to skin irritation and/or caustic burns from the portland cement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Orion Construction Corporation Guam
View Orion Construction Corporation Guam's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in GU
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342605532.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.