Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MILLER-LEAMAN, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MILLER-LEAMAN, INC. in 800 ORANGE AVE., DAYTONA BEACH, FL 32114 (NAICS 332999). OSHA activity number 342616596.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Miller-Leaman, INC. — free Get an email when a new federal OSHA severe-injury report for Miller-Leaman, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MILLER-LEAMAN, INC.
Site address
800 ORANGE AVE.
City
DAYTONA BEACH
State
FL
ZIP
32114
Mailing
800 ORANGE AVE., DAYTONA BEACH, FL 32114
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
33
Ownership type
A

2 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 20 exposed
Issued
Oct 26, 2017
Abate by
Dec 14, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a. On or about September 6, 2017, the employer's energy control program did not have employee training, periodic inspections and written procedural steps to lockout varied equipment such as but not limited to the Haas VF4, CNC machines, saws, shears and press brake thereby exposing employees to unexpected energizing, startup or release of stored energy hazards.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1910.147 C05 II C 2

Serious Gravity 5 1 instance 20 exposed
Issued
Oct 26, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii)(C)(2): Tagout devices and their means of attachment were not substantial enough to prevent inadvertent or accidental removal:  a. On or about September 6, 2017, the employer's lockout and tagout devices were not substantial enough to prevent removal.  The employer utilized a paper tag system.