FORT WORTH, TX —
OSHA Inspection: UNIWELL LABORATORIES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of UNIWELL LABORATORIES in 14801 SOVEREIGN RD., FORT WORTH, TX 76155 (NAICS 325412). OSHA activity number 342628815.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNIWELL LABORATORIES
- Site address
- 14801 SOVEREIGN RD.
- City
- FORT WORTH
- State
- TX
- ZIP
- 76155
- Mailing
- 14801 SOVEREIGN RD., FORT WORTH, TX 76155
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325412
- Employees
- 42
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C01
- Issued
- Oct 3, 2017
- Abate by
- Nov 1, 2017
- Penalty
- Initial $8,873 · Current $4,436 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. The employer failed to develop a lockout/tagout program for all pieces of equipment such as the Bartelt machine to protect employees from unexpected energization, exposing employees to electrical shock and amputation hazards.
Recent events (2)
- — I (S) $4436
- — Z (S) $8873
1910.147 C04 I
- Issued
- Oct 3, 2017
- Abate by
- Nov 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. The employer failed to ensure that specific lockout/tagout procedures were developed for each machine including but not limited to the Bartelt pouch machine, exposing employees to amputation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Oct 3, 2017
- Abate by
- Nov 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. Employees were not trained on Lockout/tagout to include the program and the procedures, exposing employees to amputation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Oct 3, 2017
- Abate by
- Nov 1, 2017
- Penalty
- Initial $6,338 · Current $3,169 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o). The belt and pulley to the Bartelt machine in the powder filling room was not guarded, exposing employees to ingoing nip point hazards.
Recent events (2)
- — I (S) $3169
- — Z (S) $6338
1910.219 E01 I
- Issued
- Oct 3, 2017
- Abate by
- Nov 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt. The belt and pulley to the Bartelt machine in the powder filling room was not guarded, exposing employees to ingoing nip point hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Uniwell Laboratories
View Uniwell Laboratories's full OSHA safety record →
More inspections in this industry (NAICS 325412)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342628815.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.