OSHA Inspection: UNIWELL LABORATORIES

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of UNIWELL LABORATORIES in 14801 SOVEREIGN RD., FORT WORTH, TX 76155 (NAICS 325412). OSHA activity number 342628815.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Uniwell Laboratories — free Get an email when a new federal OSHA severe-injury report for Uniwell Laboratories is published. One employer, no account, unsubscribe in one click.
Site address
14801 SOVEREIGN RD.
City
FORT WORTH
State
TX
ZIP
76155
Mailing
14801 SOVEREIGN RD., FORT WORTH, TX 76155
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325412
Employees
42
Ownership type
A

5 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 30 exposed
Issued
Oct 3, 2017
Abate by
Nov 1, 2017
Penalty
Initial $8,873 · Current $4,436 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    The employer failed to develop a lockout/tagout program for all pieces of equipment such as the Bartelt machine to protect employees from unexpected energization, exposing employees to electrical shock and amputation hazards.
Recent events (2)
  • — I (S) $4436
  • — Z (S) $8873

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 3, 2017
Abate by
Nov 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.   The employer failed to ensure that specific lockout/tagout procedures were developed for each machine including but not limited to the Bartelt pouch machine, exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 3, 2017
Abate by
Nov 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees.   Employees were not trained on Lockout/tagout to include the program and the procedures, exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 3, 2017
Abate by
Nov 1, 2017
Penalty
Initial $6,338 · Current $3,169 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o).        The belt and pulley to the Bartelt machine in the powder filling room was not guarded, exposing employees to ingoing nip point hazards.
Recent events (2)
  • — I (S) $3169
  • — Z (S) $6338

1910.219 E01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 3, 2017
Abate by
Nov 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt.   The belt and pulley to the Bartelt machine in the powder filling room was not guarded, exposing employees to ingoing nip point hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0