Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PHILADELPHIA RUST-PROOF COMPANY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PHILADELPHIA RUST-PROOF COMPANY, INC. in 2086 EAST WILLARD STREET, PHILADELPHIA, PA 19134 (NAICS 332813). OSHA activity number 342638160.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Philadelphia Rust-Proof Company, INC. — free Get an email when a new federal OSHA severe-injury report for Philadelphia Rust-Proof Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2086 EAST WILLARD STREET
City
PHILADELPHIA
State
PA
ZIP
19134
Mailing
2086 EAST WILLARD STREET, PHILADELPHIA, PA 19134
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
11
Ownership type
A

24 citations on file for this inspection.

1910.23 B10

Serious Gravity 5 3 instances 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 20, 2018
Penalty
Initial $4,434 · Current $2,882 Reduced
29 CFR 1910.23(b)(10): The employer did not ensure any ladder with structural or other defects was immediately tagged "Dangerous: Do Not Use" and removed from service until repaired or replaced:    (a) Treatment tank room - On or about 8/1/17, employees were allowed to use a wooden stepladder with a broken side rail to access the top of the treatment tank, exposing employees to fall hazards.
Recent events (2)
  • — I (S) $2882.1
  • — Z (S) $4434

1910.28 B01 I

Serious Gravity 5 3 instances 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 20, 2018
Penalty
Initial $2,956 · Current $1,921 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:    (a) Treatment tank room - On or about 8/1/17, employees were accessing a raised platform with an unguarded edge, exposing employees to falls of approximately 4.5ft.
Recent events (2)
  • — I (S) $1921.4
  • — Z (S) $2956

1910.134 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 27, 2018
Penalty
Initial $2,956 · Current $1,921 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    (a) Throughout the facility- On or about 8/1/17, the employer did not have a written respirator protection program when the employer required employees to use respirators such as filtering facepieces and half-face air purifying respirators.
Recent events (2)
  • — I (S) $1921.4
  • — Z (S) $2956

1910.134 E01

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a) Throughout the facility - On or about 8/1/17, the employer did not provide employees required to wear half-face air purifying respirators with medical evaluations prior to use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator and at least annually thereafter:  (a) Throughout the facility - On or about 8/1/17, the employer did not conduct fit testing prior to initial use or annually thereafter for employees required to wear tight-fitting half face air-purifying respirators while performing treatment tank servicing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 G01 I A

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:  (a) Throughout the facility - On or about 8/1/17, the employer permitted employees with facial hair that interfered with the seal to wear tight-fitting half face air-purifying respirators, exposing employees to chemical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K01

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(1): The employer did not ensure that each employee can demonstrate knowledge of items in (i)-(vii):  (a) Throughout the facility - On or about 8/1/17, the employer did not effectively train employees required to wear tight-fitting half face air-purifying respirators while performing treatment tank servicing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 L01

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(l)(1): Evaluations of the workplace were not conducted to ensure the written respiratory protection program was being effectively implemented:  (a) Throughout the facility - On or about 8/1/17, the employer did not conduct evaluations to determine if the written respirator protection program was effectively implemented.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D02

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 27, 2018
Penalty
Initial $2,217 · Current $0 Reduced
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:    (a) Throughout the facility- On or about 8/1/17, the employer did not have a written certification of hazard assessment when employees were required to wear PPE such as gloves, goggles, and aprons.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2217

1910.132 F01

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment (PPE):    (a) Throughout the facility- On or about 8/1/17, the employer did provide training to employees required to use PPE.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 5 3 instances 11 exposed
Issued
Jan 31, 2018
Abate by
Feb 20, 2018
Penalty
Initial $3,696 · Current $2,402 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    (a) Small Parts Plating - On or about 8/1/17, employee exposed to corrosive materials such as hydrochloric acid, were not provided with immediate access to eyewash stations.    (b) Hard anodizing - On or about 8/1/17, employee exposed to corrosive materials such as hydrochloric acid, were not provided with immediate access to eyewash stations.    (c) Zinc Plating - On or about 8/1/17, employee exposed to corrosive materials such as hydrochloric acid, were not provided with immediate access to eyewash stations.
Recent events (2)
  • — I (S) $2402.4
  • — Z (S) $3696

1910.178 A04

Serious Gravity 5 3 instances 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 20, 2018
Penalty
Initial $3,696 · Current $2,402 Reduced
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval:    (a) Loading dock - On or about 8/1/17, employees were operating a forklift in which the employer had installed fork extensions without the approval of the forklift manufacturer.
Recent events (2)
  • — I (S) $2402.4
  • — Z (S) $3696

1910.178 A05

Deleted Serious Gravity 5 3 instances 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered:  (a) Loading dock - On or about 8/1/17, employees were operating a forklift with fork extensions without its capacity updated on the data plate.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 II

Serious Gravity 5 3 instances 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a forklift:  (a) Loading dock - On or about 8/1/17, the employer did not provide training to each employee prior to permitting the employee to operate a forklift.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L06

Deleted Serious Gravity 1 3 instances 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  (a) Loading dock - On or about 8/1/17, the employer did not certify that each employee was trained and evaluated in forklift operation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 Q07

Serious Gravity 5 3 instances 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:  (a) Loading dock - On or about 8/1/17, the employer did not examine forklifts daily before being placed in service.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A05

Serious Gravity 10 1 instance 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 20, 2018
Penalty
Initial $5,174 · Current $3,363 Reduced
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:     (a) Small Parts Plating - On or about 8/1/17, a fan blade was not guarded, exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $3363.1
  • — Z (S) $5174

1910.219 D01

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):   (a) Small Parts Plating - On or about 8/1/17, a pulley driving a fan was not guarded, exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E03 I

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 31, 2018
Abate by
Feb 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):  (a) Small Parts Plating - On or about 8/1/17, a vertical V-Belt driving a fan was not guarded, exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07

Serious Gravity 10 3 instances 11 exposed
Issued
Jan 31, 2018
Abate by
Feb 20, 2018
Penalty
Initial $5,174 · Current $3,363 Reduced
29 CFR 1910.303(b)(7): Electrical equipment was not installed in a neat and workmanlike manner.                (a) Zinc Plating - On or about 8/1/17, wiring operating at 50 volts or greater was not installed in a completed installation to enclose all insulated conductors and components, exposing employees to shock hazards.
Recent events (2)
  • — I (S) $3363.1
  • — Z (S) $5174

1910.303 B07 I

Serious Gravity 10 3 instances 11 exposed
Issued
Jan 31, 2018
Abate by
Feb 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(i):  Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.              (a) Tank room - On or about 8/1/17, An electrical cabinet was opened exposing wiring operating at 50 volts or greater, exposing employees to shock hazards.  (b) Tank room - On or about 8/1/17, Unused openings on electrical disconnects were not effectively closed as required exposing wiring operating at 600 volts, exposing employees to shock hazards.  (c) Zinc Plating room - On or about 8/1/17, Unused openings on electrical circuit breaker panels were not effectively closed as required exposing wiring operating at 240 volts, exposing employees to shock hazards.  (d) Zinc Plating room - On or about 8/1/17, Unused openings on electrical boxes were not effectively closed as required exposing wiring operating at greater than 50 volts, exposing employees to shock hazards.  (e) X-Ray room - On or about 8/1/17, A wall outlet did not have a faceplate exposing wiring operating at 120 volts, exposing employees to shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 IV

Serious Gravity 5 3 instances 11 exposed
Issued
Jan 31, 2018
Abate by
Feb 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut or deteriorated by corrosion, chemical action or overheating.                (a) Tank room - On or about 8/1/17, An electrical cabinet was opened and could not be closed exposing wiring operating at 50 volts or greater, exposing employees to shock hazards.  (b) Tank room - On or about 8/1/17, electrical disconnect enclosures and pull handles were corroded, exposing employees to shock hazards.  (c) Zinc Plating room - On or about 8/1/17, electrical circuit breaker panels were corroded, exposing employees to shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 II

Serious Gravity 5 3 instances 11 exposed
Issued
Jan 31, 2018
Abate by
Feb 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:              (a) Small parts plating - On or about 8/1/17, a flexible cord that was energizing plating equipment was spliced, exposing employees to shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Deleted Serious Gravity 5 1 instance 11 exposed
Issued
Jan 31, 2018
Abate by
Feb 27, 2018
Penalty
Initial $3,696 · Current $0 Reduced
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) Throughout the facility - On or about 8/1/17, employees are not provided training on hazardous chemicals such as, but not limited to hydrochloric acid, magnesium phosphate, etc. in their work areas.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3696

View Philadelphia Rust-Proof Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342638160.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.