Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LEOTAUR TECHNOLOGY GROUP, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of LEOTAUR TECHNOLOGY GROUP, INC. in 111 LEHIGH STREET, MACUNGIE, PA 18062 (NAICS 326191). OSHA activity number 342639655.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Leotaur Technology Group, INC. — free Get an email when a new federal OSHA severe-injury report for Leotaur Technology Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
111 LEHIGH STREET
City
MACUNGIE
State
PA
ZIP
18062
Mailing
111 LEHIGH STREET, MACUNGIE, PA 18062
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326191
Employees
21
Ownership type
A

8 citations on file for this inspection.

1910.107 C07

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 7, 2017
Abate by
Dec 27, 2017
Penalty
Initial $4,780 · Current $4,780

Hazardous substances 22808470

29 CFR 1910.107(c)(7): Electric lamps outside of but within 20 feet of spraying area(s), and not separated therefrom by partition(s), were not protected from mechanical injury by suitable guards or by location:   a)  Leaotaur Technology Group - On or about September 14, 2017, an employee spray coating in the spray booth with Gel Coat, a flammable material, was exposed to fire and burn hazards as there were three 16" x 16" openings in the ceiling of the spray booth each with an unprotected incandescent light bulb located 6 inches above the booth openings.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states that employees and their representatives were informed of this abatement.
Recent events (3)
  • — F (S) $4780
  • — C (S) $4780
  • — Z (S) $4780

1910.95 K02

Repeat 1 instance 4 exposed
Issued
Dec 7, 2017
Abate by
Dec 27, 2017
Penalty
Initial $3,984 · Current $500 Reduced

Hazardous substances 81108111

29 CFR 1910.95(k)(2): The training program was not repeated annually for each employee included in the hearing conservation program:    a) Leaotaur Technology Group - On or about September 14, 2017, employees grinding granite counter tops in the Granite Counter Top Department are exposed to continuous noise exposures in excess of 85 dBA for a daily eight hour time weighted average (TWA) and the employer had not provided training since March 2016.      Leotaur Technology Group, d/b/a Lehigh Surfaces was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.95(k)(2), which was contained in OSHA inspection number 1099640, citation number 2, item number 3b and was affirmed as a final order on February 19, 2016, with respect to a workplace located at 111 Lehigh Street, Macungie, PA 18062.
Recent events (3)
  • — F (R) $500
  • — C (R) $3984
  • — Z (R) $3984

1910.107 B05 I

Repeat Gravity 5 1 instance 1 exposed
Issued
Dec 7, 2017
Abate by
Dec 27, 2017
Penalty
Initial $19,919 · Current $10,554 Reduced

Hazardous substances 22808470

29 CFR 1910.107(b)(5)(i):  The average air speed over the open face of the paint spray booth was less than 100 linear feet per minute.    a) Leaotaur Technology Group - On or about September 14, 2017, an employee spray coating in the spray booth with Gel Coat, a flammable material, was exposed to inhalation and burn hazards as the average air velocity across the face of the booth was 45 feet per minute.    Leotaur Technology Group, d/b/a Lehigh Surfaces was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.107(b)(5)(i), which was contained in OSHA inspection number 1099640, citation number 2, item number 2b and was affirmed as a final order on February 19, 2016, with respect to a workplace located at 111 Lehigh Street, Macungie, PA 18062.
Recent events (3)
  • — F (R) $10553.5
  • — C (R) $19919
  • — Z (R) $19919

1910.107 F03

Repeat Gravity 5 1 instance 2 exposed
Issued
Dec 7, 2017
Abate by
Dec 27, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 22808470

29 CFR 1910.107(f)(3): Sprinklers protecting spraying areas were not kept as free from deposits as practical by cleaning daily if necessary:  a)  Leaotaur Technology Group - On or about September 14, 2017, an employee spray coating in the spray booth with Gel Coat, a flammable material, was exposed to fire and burn hazards as there was an accumulation of combustible residue on the booth sprinkler heads located in front of and behind the filters.  Leotaur Technology Group, d/b/a Lehigh Surfaces was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.107(f)(3), which was contained in OSHA inspection number 896067, citation number 1, item number 3b and was affirmed as a final order on August 6, 2013, with respect to a workplace located at 111 Lehigh Street, Macungie, PA 18062.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.
Recent events (3)
  • — F (R) $0
  • — C (R) $0
  • — Z (R) $0

1910.107 G02

Repeat Gravity 5 1 instance 1 exposed
Issued
Dec 7, 2017
Abate by
Dec 27, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 22808470

29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:   a) Leaotaur Technology Group - On or about September 14, 2017, an employee spray coating in the spray booth with Gel Coat, a flammable material, was exposed to fire and burn hazards as there was an accumulation of combustible residue on the booth interior walls, floors, and conveyors.  Leotaur Technology Group, d/b/a Lehigh Surfaces was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.107(g)(2), which was contained in OSHA inspection number 1099640, citation number 2, item number 2c and was affirmed as a final order on February 19, 2016, with respect to a workplace located at 111 Lehigh Street, Macungie, PA 18062.
Recent events (3)
  • — F (R) $0
  • — C (R) $0
  • — Z (R) $0

1910.134 F02

Repeat 1 instance 3 exposed
Issued
Dec 7, 2017
Abate by
Dec 27, 2017
Penalty
Initial $3,984 · Current $500 Reduced

Hazardous substances 22808470

29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:      a) Leaotaur Technology Group - On or about September 14, 2017, an employee was required to wear a 3M elastomeric full face organic vapor cartridge air purifying respirator while exposed to the hazards of spray painting molds with Gel Coating containing Styrene, and an appropriate fit test was not provided annually.     Leotaur Technology Group, d/b/a Lehigh Surfaces was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.134.(f)(1), which was contained in OSHA inspection number 1099640, citation number 2, item number 3b and was affirmed as a final order on February 19, 2016, with respect to a workplace located at 111 Lehigh Street, Macungie, PA 18062.
Recent events (3)
  • — F (R) $500
  • — C (R) $3984
  • — Z (R) $3984

1910.134 G01 I A

Repeat 1 instance 3 exposed
Issued
Dec 7, 2017
Abate by
Dec 27, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 22808470

29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:    a) Leaotaur Technology Group - On or about September 14, 2017, an employee was required to wear a 3M elastomeric full face organic vapor cartridge air purifying respirator while exposed to the hazards of spray painting molds with Gel Coating containing Styrene, and the employee had facial hair that came between the sealing surface of the facepiece.   Leotaur Technology Group, d/b/a Lehigh Surfaces was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.134(g)(1)(i)(A), which was contained in OSHA inspection number 1099640, citation number 2, item number 3c and was affirmed as a final order on February 19, 2016, with respect to a workplace located at 111 Lehigh Street, Macungie, PA 18062.
Recent events (3)
  • — F (R) $0
  • — C (R) $0
  • — Z (R) $0

1910.134 K

Repeat 1 instance 3 exposed
Issued
Dec 7, 2017
Abate by
Dec 27, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 22808470

29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary:  a) Leaotaur Technology Group - On or about September 14, 2017, an employee was required to wear a 3M elastomeric full face organic vapor cartridge air purifying respirator while exposed to the hazards of spray painting molds with Gel Coating containing Styrene, and the employee was not provided annual respirator training.   Leotaur Technology Group, d/b/a Lehigh Surfaces was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard 29 CFR 1910.134(k), which was contained in OSHA inspection number 1099640, citation number 1 item number 2 and was affirmed as a final order on February 19, 2016, with respect to a workplace located at 111 Lehigh Street, Macungie, PA 18062.
Recent events (3)
  • — F (R) $0
  • — C (R) $0
  • — Z (R) $0

View Leotaur Technology Group, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342639655.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.