OAKMONT, PA —
OSHA Inspection: THERMO-TWIN INDUSTRIES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of THERMO-TWIN INDUSTRIES, INC. in 1155 ALLEGHENY AVENUE, OAKMONT, PA 15139 (NAICS 332321). OSHA activity number 342640901.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THERMO-TWIN INDUSTRIES, INC.
- Site address
- 1155 ALLEGHENY AVENUE
- City
- OAKMONT
- State
- PA
- ZIP
- 15139
- Mailing
- 1155 ALLEGHENY AVENUE, OAKMONT, PA 15139
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 88
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.95 C01
- Issued
- Oct 3, 2017
- Abate by
- Nov 6, 2017
- Penalty
- Initial $8,873 · Current $5,500 Reduced
8111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: a) In the Facility, on or about September 22, 2017 - The employer did not institute a continuing effective hearing conservation program when employee noise exposures exceeded an 8-hour time-weighted average sound level of 85 dBA. An employee designated as a Cutter was exposed to noise at a level of 196.5% of the allowable limit during a 315 minute sampling period on September 22, 2017. This exposure is equivalent to a sound level of 94.9 dBA for the dose and time of employee exposure and is 3.9 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required. b) In the Facility, on or about September 22, 2017 - An employee designated as a Screen Maker was exposed to noise at a level of 72.8% of the allowable limit during a 316 minute sampling period on September 22, 2017. This exposure is equivalent to a sound level of 87.7 dBA for the dose and time of employee exposure and is 1.5 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required.
Recent events (2)
- — I (S) $5500
- — Z (S) $8873
1910.95 G01
- Issued
- Oct 3, 2017
- Abate by
- Nov 6, 2017
- Penalty
- Initial $0 · Current $0
8111
General-duty citation text
29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels: a) In the Facility, on or about September 22, 2017 - The employer did not establish and maintain an audiometric testing program when employee noise exposures equaled or exceeded an 8-hour time-weighted average exposure of 85 decibels. (See descriptions of employee noise exposures in Citation 1, Item 1, Instances a and b).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 K01
- Issued
- Oct 3, 2017
- Abate by
- Nov 6, 2017
- Penalty
- Initial $0 · Current $0
8111
General-duty citation text
29 CFR 1910.95(k)(1): The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k): a) In the Facility, on or about September 22, 2017 - The employer did not provide noise training to employees whose noise exposures equaled or exceeded an 8-hour time-weighted average exposure of 85 decibels. (See descriptions of employee noise exposures in Citation 1, Item 1, Instances a and b).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 L01
- Issued
- Oct 3, 2017
- Abate by
- Nov 6, 2017
- Penalty
- Initial $0 · Current $0
8111
General-duty citation text
29 CFR 1910.95(l)(1): The employer did not make available to affected employees or their representatives copies of 29 CFR 1910.95 and did not post a copy in the workplace: a) In the Facility, on or about September 22, 2017 - The employer did not post a copy of the Occupational Noise Standard, 29 CFR 1910.95 in the workplace.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 D01
- Issued
- Oct 3, 2017
- Abate by
- Oct 16, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(d)(1): Portable fire extinguishers were not selected based on the classes of anticipated workplace fires and on the size and degree of hazard that would affect their use: a) Saw Area, on or about September 15, 2017 - The employer did not select a portable fire extinguisher based on the appropriate class of fire. Class A fire extinguishers were provided in the saw area where aluminum metal dust is generated. ABATEMENT NOTE: Class D fire extinguishers are appropriate for combustible metal fires.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Thermo-Twin Industries, INC.
View Thermo-Twin Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332321)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342640901.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.