Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RUBI CONSTRUCTION LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RUBI CONSTRUCTION LLC in LOTS 211 THRU 214 LARK WAY, MECHANICSBURG, PA 17055 (NAICS 238160). OSHA activity number 342645116.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rubi Construction LLC — free Get an email when a new federal OSHA severe-injury report for Rubi Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
LOTS 211 THRU 214 LARK WAY
City
MECHANICSBURG
State
PA
ZIP
17055
Mailing
6204 BROWN AVENUE APARTMENT B1, BALTIMORE, MD 21224
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

6 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 2 exposed
Issued
Jan 26, 2018
Abate by
Feb 7, 2018
Penalty
Initial $311 · Current $311
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:  On or about January 26, 2018, the employer did not provide abatement documentation regarding citation 1 item 1, and citation 2 items 2b, 2c and 2d within 10 days of the abatement date of November 20, 2017.
Recent events (1)
  • — Z (O) $311

1926.501 B13

Serious Gravity 10 1 instance 10 exposed
Issued
Oct 24, 2017
Abate by
Nov 20, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a)  Roof - Employees conducting roofing operations on a steep residential roof donned a body harness as part of a personal fall arrest system but did not attach to an anchor point and were exposed to an approximate 31 foot fall hazard to the ground below, on or about September 18, 2017.  Abatement certification and documentation required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $3803

1926.1053 B01

Serious Gravity 10 1 instance 10 exposed
Issued
Oct 24, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a)  Job Site - Employees used a 40 foot portable Werner extension ladder to access/egress the roof and the ladder side rails extended approximately 12 inches above the eave, exposing employees to an approximate 31 foot fall hazard, on or about September 18, 2017.  No abatement certification or documentation required.
Recent events (1)
  • — Z (S) $3803

1926.1053 B08

Serious Gravity 10 1 instance 10 exposed
Issued
Oct 24, 2017
Abate by
Nov 20, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways were not secured to prevent accidental displacement, or barricaded to keep the activities or traffic away from the ladder:  a)  Job Site - Employees placed a 40 foot portable Werner extension ladder at the entrance to the townhome that was not secured and/or barricaded to prevent accidental displacement to access the roof located approximately 31 feet above ground, on or about September 18, 2017.  Abatement certification and documentation required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $0

1926.1053 B09

Serious Gravity 10 1 instance 10 exposed
Issued
Oct 24, 2017
Abate by
Nov 20, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(9): The area around the top and bottom of ladders was not kept clear:  a)  Job Site - Employees used a 40 foot portable Werner extension ladder to access/egress the roof and the bottom area of the ladder was cluttered with debris, on or about September 18, 2017.  Abatement certification and documentation required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $0

1926.1053 B16

Serious Gravity 10 1 instance 10 exposed
Issued
Oct 24, 2017
Abate by
Nov 20, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identified them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired:  a)  Job Site - A 40 foot portable Werner extension ladder with bent side rails, was used to access/egress the roof located approximately 31 feet above the ground, on or about September 18, 2017.  Abatement certification and documentation required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.  Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $0

View Rubi Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342645116.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.