Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CILIA'S LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CILIA'S LLC in 121 WEBSTER AVE, GOSHEN, NY 10924 (NAICS 238320). OSHA activity number 342645686.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cilia'S LLC — free Get an email when a new federal OSHA severe-injury report for Cilia'S LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CILIA'S LLC
Site address
121 WEBSTER AVE
City
GOSHEN
State
NY
ZIP
10924
Mailing
15 PARK AVE, MIDDLETOWN, NY 10940
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
12
Ownership type
A

6 citations on file for this inspection.

1926.404 B01 III C

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 7, 2018
Abate by
Mar 6, 2018
Penalty
Initial $2,217 · Current $1,600 Reduced
29 CFR 1926.404(b)(1)(iii)(C): The employer did not ensure that each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, were visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage:    a) Worksite - On or about September 20, 2017 the employer did not ensure that an extension cord plug end was without insulation damage in that the inside wires were exposed due to the insulation being pulled away from plug end potentially exposing employees to electric shock.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2217

1926.405 A02 II I

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 7, 2018
Abate by
Mar 6, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points:  a) Worksite - On or about September 20, 2017 an extension cord was not protected from the pinch point of being run through a window potentially exposing employees to electric shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 7, 2018
Abate by
Feb 13, 2018
Penalty
Initial $3,696 · Current $1,600 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    a) Roof - On or about September 18, 2017, an employee was exposed to fall hazards when working on an approximately 10 on 12 pitched roof of approximately 12.5 feet high without fall protection.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $3696

1926.503 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 7, 2018
Abate by
Feb 13, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) Worksite - On or about September 18, 2017, the employer did not provide a fall protection training program for employees potentially exposed to fall hazards and for the employees recognize the fall hazards and how to minimize these fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B04

Serious Gravity 1 1 instance 1 exposed
Issued
Feb 7, 2018
Abate by
Feb 27, 2018
Penalty
Initial $2,217 · Current $1,700 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    a) Worksite - On or about September 20, 2017 an employee was exposed to fall hazards of approximately 4 feet due to using a 6 foot long Werner self-supporting step ladder as a non-self-supporting ladder to paint the side of the house.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $2217

1926.1060 A

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 7, 2018
Abate by
Feb 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards:  a) Worksite - On or about September 20, 2017 the employer did not provide a ladder and stairway training program to enable employees to recognize hazards related to ladders and stairways and train the employees on procedures to follow when using ladders and stairways.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Cilia'S LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342645686.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.