MERRILL, WI —
OSHA Inspection: AMERICAN MODERN EXTERIORS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMERICAN MODERN EXTERIORS LLC in 3209 EAST MAIN STREET, MERRILL, WI 54452 (NAICS 238160). OSHA activity number 342653599.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN MODERN EXTERIORS LLC
- Site address
- 3209 EAST MAIN STREET
- City
- MERRILL
- State
- WI
- ZIP
- 54452
- Mailing
- 821 EAST 1ST AVENUE STE. 6, APPLETON, WI 54911
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 14
- Ownership type
- A
Citations
4 citations on file for this inspection.
1903.19 C01
- Issued
- Apr 17, 2018
- Abate by
- May 8, 2018
- Penalty
- Initial $311 · Current $311
General-duty citation text
29 CFR 1903.19(c)(1): 29 CFR 1903.19(c)(1): The employer failed to certify to OSHA (the Agency) that the following item(s) were abated within 10 calendar days after the abatement date: a) American Modern Exteriors, LLC, did not provide abatement within 10 calendar days after the abatement date on all the cited items.
Recent events (1)
- — Z (O) $311
1903.19 D01
- Issued
- Apr 17, 2018
- Abate by
- May 8, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1903.19(d)(1): The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. a) American Modern Exteriors, LLC failed to provide documentation demonstrating the abatement method and completion of the following items as cited: a) Citation 1, Item 1: Establish and maintain a program to address job site safety and health and provide a competent person to address recognized hazards for workers. b) Citation 1, Item 2: Ensure that fall protection is provided and utilized during construction work at heights greater than 6 feet.
Recent events (1)
- — Z (O) $0
1926.20 B02
- Issued
- Jan 18, 2018
- Abate by
- Feb 15, 2018
- Penalty
- Initial $5,174 · Current $5,174
General-duty citation text
29 CFR 1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers. On or about September 21, 2017 at 3209 East Main Street in Merrill, WI, employees were exposed to multiple hazards, including but not limited to, falls from elevated surfaces and ladders, struck by flying objects, fire, and amputations, while re-roofing a two story hotel building when the employer did not conduct inspections to identify and correct recognizable hazards and/or to enforce personal protection equipment use.
Recent events (1)
- — Z (S) $5174
1926.501 B10
- Issued
- Jan 18, 2018
- Abate by
- Feb 23, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted. On or about September 21, 2017 at 3209 East Main Street in Merrill, employees were working in a roof surface 17 ft. above surface level without utilizing any fall protection equipment.
Recent events (1)
- — Z (S) $0
More inspections at American Modern Exteriors LLC
View American Modern Exteriors LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342653599.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.