Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FABRICATED COMPONENTS, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FABRICATED COMPONENTS, INC in 2018 WEST MAIN ST P.O. BOX 431, STROUDSBURG, PA 18360 (NAICS 332322). OSHA activity number 342659539.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fabricated Components, INC — free Get an email when a new federal OSHA severe-injury report for Fabricated Components, INC is published. One employer, no account, unsubscribe in one click.
Site address
2018 WEST MAIN ST P.O. BOX 431
City
STROUDSBURG
State
PA
ZIP
18360
Mailing
PO BOX 431, STROUDSBURG, PA 18360
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
53
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 10 exposed
Issued
Dec 1, 2017
Abate by
Apr 6, 2018
Penalty
Initial $5,387 · Current $5,000 Reduced
OSH ACT of 1970 Section (5)(a)(1):  Section 5(a)(1) of the Occupational Safety and Health Act of 1070:  The employer does not furnish employment and a place of employment which are free from recognized hazards that are causing or likely to cause death or serious physical harm to employees in that employees were operating press brakes with an unprotected foot pedal actuator:      a) Press Brake Dept.: Employees were operating the Chicago Dreis & Krump model 4510-D, (s/n P8461) press brake with an unprotected foot pedal actuator, exposing employees to the unexpected machine operation and caught-in/by hazards, as observed on or about September 25, 2017.      b) Press Brake Dept.: Employees were operating the Chicago Dreis & Krump model 410-D, (s/n P8363) press brake with an unprotected foot pedal actuator, exposing employees to the unexpected machine operation and caught-in/by, as observed on or about September 25, 2017.                                                            ABATEMENT CERTIFICATION IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $5387

1910.212 A03 II

Serious Gravity 5 3 instances 5 exposed
Issued
Dec 1, 2017
Abate by
Jul 31, 2018
Penalty
Initial $5,387 · Current $5,000 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):      a) Press Brake Dept.:  The point of operation for the Cincinnati 9 press brake was not guarded. Employees were exposed to caught-by hazards by the ram as observed on or about September 25, 2017.    b) Press Brake Dept.:  The point of operation for the Chicago Dreis & Krump model 410-D press brake was not guarded. Employees were exposed to caught-by hazards by the ram as observed on or about September 25, 2017.    c) Press Brake Dept.:  The point of operation for the Chicago Dreis & Krump model 4510-D press brake was not guarded. Employees were exposed to caught-by hazards by the ram as observed on or about September 25, 2017.                                         ABATEMENT CERTIFICATION IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $5387

1910.147 C01

Deleted Serious Gravity 5 1 instance 20 exposed
Issued
Dec 1, 2017
Abate by
Dec 28, 2017
Penalty
Initial $5,387 · Current $0 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  a) Throughout Facility:  The employer did not establish an energy control program consisting of procedures, employee training, and periodic inspections, for those employees, including machine operators, maintenance personnel, and other personnel, who were working in proximity or performing service and maintenance on machines with multiple energy sources, including but not limited to press brakes, to protect the employees from the unexpected energization, startup or release of stored energy, exposing employees to crushing, electrical, thermal, and amputation hazards, on or about September 25, 2017.                                                    ABATEMENT CERTIFICATION REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5387

1910.252 B02 III

Other-than-serious 1 instance 20 exposed
Issued
Dec 1, 2017
Abate by
Apr 20, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  a) Production Area:  Employees required to travel through the welding areas were not protected from the rays by flameproof screens or shields, as observed on or about September 25, 2017.                                               ABATEMENT CERTIFICATION IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Fabricated Components, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342659539.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.