Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EAGLE GRAPHICS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EAGLE GRAPHICS INC. in 150 N MOYER STREET, ANNVILLE, PA 17003 (NAICS 323111). OSHA activity number 342660511.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eagle Graphics INC. — free Get an email when a new federal OSHA severe-injury report for Eagle Graphics INC. is published. One employer, no account, unsubscribe in one click.
Establishment
EAGLE GRAPHICS INC.
Site address
150 N MOYER STREET
City
ANNVILLE
State
PA
ZIP
17003
Mailing
150 N MOYER STREET, ANNVILLE, PA 17003
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
50
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 29, 2017
Abate by
Feb 16, 2018
Penalty
Initial $4,310 · Current $2,741 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) 150 N Moyer Street: The employer did not ensure that employees were protected from rotating parts from the Schriber Collator, thereby exposing employees to caught in hazards on or before September 20, 2017    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $2741.25
  • — Z (S) $4310

1910.305 G02 III

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 29, 2017
Abate by
Jan 26, 2018
Penalty
Initial $4,310 · Current $2,741 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was not provided that would have prevented tension from being directly transmitted to joints or terminal screws:    a) 150 N Moyer street - A flexible cord plugged into the outlet under the Shriber Collator outside insulation was separated from the plug exposing employees to shock hazards on or before September 20, 2017.    Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $2741.25
  • — Z (S) $4310

1910.334 A02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 29, 2017
Abate by
Jan 26, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  a) 150 N Moyer street - The employer did not ensure that a damaged extension cord which was plugged into a power outlet under the Schriber Collator was visually inspected before use, allowing the machine operator to be exposed to electrical shocks on or before September 20, 2017.   Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B02

Deleted Other-than-serious 1 instance 20 exposed
Issued
Dec 29, 2017
Abate by
Jan 11, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  150 N Moyer Street - The rear door was not labeled as an exit, on or about September 20, 2017  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Eagle Graphics INC.'s full OSHA safety record →