Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CUSTOM TRUSS LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CUSTOM TRUSS LLC in 1890 WEST ATLANTIC AVENUE, DELRAY BEACH, FL 33444 (NAICS 238130). OSHA activity number 342668134.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Custom Truss LLC — free Get an email when a new federal OSHA severe-injury report for Custom Truss LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CUSTOM TRUSS LLC
Site address
1890 WEST ATLANTIC AVENUE
City
DELRAY BEACH
State
FL
ZIP
33444
Mailing
1890 WEST ATLANTIC AVENUE, DELRAY BEACH, FL 33444
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
30
Ownership type
A

4 citations on file for this inspection.

1910.95 I02

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 26, 2017
Penalty
Initial $6,972 · Current $3,486 Reduced
29 CFR 1910.95(i)(2): The employer did not ensure that hearing protectors were worn by employees whose exposures equaled or exceeded an 8-hour time-weighted average of 85 decibels:    On or about 9/28/2017, at the above addressed jobsite, the employer did not ensure employees in the pull saw area would use hearing protection.
Recent events (2)
  • — I (S) $3486
  • — Z (S) $6972

1910.305 G01 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Oct 26, 2017
Abate by
Nov 30, 2017
Penalty
Initial $8,365 · Current $4,183 Reduced
29 CFR 1910.305(g)(1)(iv):   Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure:        On or about 9/28/2017, at the above address jobsite, the employer had used extension cords to power the lighting in the cable shop.
Recent events (2)
  • — I (S) $4182.5
  • — Z (S) $8365

1910.141 C01 I

Other-than-serious 1 instance 24 exposed
Issued
Oct 26, 2017
Abate by
Dec 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.141(c)(1)(i): At this establishment, toilet facilities were not provided for employees in accordance with TABLE J-1 of this standard:  On or about 9/28/2017, at the above address jobsite, the employer had one (1) toilet available to employees while having approximately twenty four (24) employees in the shop.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.334 A02 II

Other-than-serious 1 instance 2 exposed
Issued
Oct 26, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): If there was a defect or evidence of damage that could have exposed an employee to injury, the defective or damaged item was not removed from service, and an employee used it before repairs and tests necessary to render the equipment safe were made:  On or about 9/28/2017, at the above addressed jobsite, an extension cord's outer sheath insulation was damaged, exposing the internal conductors.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Custom Truss LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342668134.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.