MILLRY, AL —
OSHA Inspection: LASSITER LUMBER, L.L.C.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LASSITER LUMBER, L.L.C. in 107 MILLRY MILL ROAD, MILLRY, AL 36558 (NAICS 321113). OSHA activity number 342668167.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LASSITER LUMBER, L.L.C.
- Site address
- 107 MILLRY MILL ROAD
- City
- MILLRY
- State
- AL
- ZIP
- 36558
- Mailing
- 107 MILLRY MILL ROAD, MILLRY, AL 36558
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 86
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A05
- Issued
- Jan 25, 2018
- Abate by
- Feb 2, 2018
- Penalty
- Initial $9,053 · Current $4,750 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: a) Planar Mill (Air Compressor Area): On or about September 25, 2017, and at times prior thereto, the employer exposed employees to amputation hazards from equipment such as but not limited to the GD15 HP Air Compressor when employees were required to clean and operate the machinery around the fan unit without the blades being guarded.
Recent events (2)
- — I (S) $4750
- — Z (S) $9053
1910.219 C02 I
- Issued
- Jan 25, 2018
- Abate by
- Feb 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) Planar Mill (Planar Conveyor System - Grader): On or about September 25, 2017, and at times prior thereto, the employer did not ensure that the horizontal shaft on equipment such as but not limited to the Planar Conveyor System - Grader was not protected by a stationary casing, exposing employees to amputation hazards and the hazard of being caught in the rotating shaft.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Jan 25, 2018
- Abate by
- Feb 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Planar Mill (Air Compressor Area): On or about September 25, 2017, and at times prior thereto, the employer did not ensure that equipment such as but not limited to the GD15 HP Air Compressor's pulley was guarded which exposed employees performing service and maintenance to amputation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 E03 I
- Issued
- Jan 25, 2018
- Abate by
- Feb 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): a) Planar Mill (Air Compressor Area): On or about September 25, 2017, and at times prior thereto, the employer did not ensure that equipment such as but not limited to the GD15 HP Air Compressor's fan belt was not guarded which exposed employees performing service and maintenance to amputation hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Jan 25, 2018
- Abate by
- Feb 2, 2018
- Penalty
- Initial $6,467 · Current $4,750 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Planar Mill (L/O Switch 1 - LockOut Point): On or about September 25, 2017, and at times prior thereto, the employer did not ensure that knockout holes and openings were sealed on electrical enclosures exposing employees to arc flash, electrical shock, fire and explosive hazards. b) Repair Shop (Mechanic's Area - Electrical Wall Outlet): On or about September 25, 2017, and at times prior thereto, the employer did not ensure that knockout holes and openings were sealed on electrical enclosures exposing employees to arc flash, electrical shock, fire and explosive hazards.
Recent events (2)
- — I (S) $4750
- — Z (S) $6467
More inspections at Lassiter Lumber, L.L.C.
View Lassiter Lumber, L.L.C.'s full OSHA safety record →
More inspections in this industry (NAICS 321113)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342668167.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.