Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U. S. DEPT. OF DEFENSE - U. S. ARMY CORP. OF ENGINEERS - WARM SPRINGS DAM

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U. S. DEPT. OF DEFENSE - U. S. ARMY CORP. OF ENGINEERS - WARM SPRINGS DAM in 3333 SKAGGS SPRINGS ROAD, GEYSERVILLE, CA 95441 (NAICS 928110). OSHA activity number 342677283.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U. S. Dept. of Defense - U. S. Army Corp. of Engineers - Warm Springs DAM — free Get an email when a new federal OSHA severe-injury report for U. S. Dept. of Defense - U. S. Army Corp. of Engineers - Warm Springs DAM is published. One employer, no account, unsubscribe in one click.
Site address
3333 SKAGGS SPRINGS ROAD
City
GEYSERVILLE
State
CA
ZIP
95441
Mailing
3333 SKAGGS SPRINGS ROAD, GEYSERVILLE, CA 95441
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
17
Ownership type
D

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 2 instances 2 exposed
Issued
Nov 21, 2017
Abate by
Dec 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  In the following locations equipment was not provided with safeguarding:  a) Maintenance Shop: Rockwell  10 inch table saw was not provided with the blade guards to protect the operator from hazards created by point of operation.  b) Maintenance Shop: Dayton drill press was not provided with a guard to protect employees from flying chips and sparks.  c) COHO Fish Hatchery Building: A Ridgid 10 inch table saw was not provided with the blade guards to protect the operator from hazards created by point of operation.
Recent events (1)
  • — Z (S) $0

1910.215 A04

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 21, 2017
Abate by
Dec 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  Maintenance Shop: The work rest on the Dayton 7 inch pedestal grinder was not adjusted to 1/8th of an inch. The work rest was measured at one inch and 1/8th of inch away from the wheel from the abrasive wheel.
Recent events (1)
  • — Z (S) $0

1910.243 C03

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 21, 2017
Abate by
Dec 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.243(c)(3): Abrasive wheels used on right angle head grinders were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel:  Welding shop: A DeWalt portable right angle grinder with 4.5 inch abrasive grinding wheel attachment was missing the abrasive wheel guard.
Recent events (1)
  • — Z (S) $0

1910.110 B06 VII

Other-than-serious 1 instance 1 exposed
Issued
Nov 21, 2017
Abate by
Dec 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.110(b)(6)(vii): The separation between liquefied petroleum gas containers and flammable liquid tanks was not 20 feet.    Welding Shop:  An oxygen gas cylinder in storage was not separated 20 feet apart from a flammable acetylene cylinder.
Recent events (1)
  • — Z (O) $0

View U. S. Dept. of Defense - U. S. Army Corp. of Engineers - Warm Springs DAM's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342677283.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.