Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U. S. DEPT. OF DEFENSE - U. S. ARMY CORP. OF ENGINEERS - WARM SPRINGS DAM

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U. S. DEPT. OF DEFENSE - U. S. ARMY CORP. OF ENGINEERS - WARM SPRINGS DAM in 3333 SKAGGS SPRINGS ROAD, GEYSERVILLE, CA 95441 (NAICS 928110). OSHA activity number 346381718.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U. S. Dept. of Defense - U. S. Army Corp. of Engineers - Warm Springs DAM — free Get an email when a new federal OSHA severe-injury report for U. S. Dept. of Defense - U. S. Army Corp. of Engineers - Warm Springs DAM is published. One employer, no account, unsubscribe in one click.
Site address
3333 SKAGGS SPRINGS ROAD
City
GEYSERVILLE
State
CA
ZIP
95441
Mailing
3333 SKAGGS SPRINGS ROAD, GEYSERVILLE, CA 95441
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
16
Ownership type
D

3 citations on file for this inspection.

1910.23 B10

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 3, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.23(b)(10):The employer did not ensure any ladder with structural or other defects was immediately tagged "Dangerous: Do Not Use" or with similar language in accordance with 1910.145 and removed from service until repaired in accordance with 1910.22(d), or replaced.  Located in the maintenance shop, a wooden ladder leading to a loft area was available for employee use. The wood side rail of the ladder had a large split where the metal handrail and the wooden side rail were connected. Employees who work in the maintenance shop were exposed to a fall hazard.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 3, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.212(a)(1):Types of guarding. One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.  Located in the maintenance shop, a Rikon Model #30-240 20" drill press did not have a guard at the point of operation. Employees are exposed to amputation and laceration hazards.
Recent events (1)
  • — Z (S) $0

1910.157 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 3, 2023
Abate by
Feb 21, 2023
Penalty
Initial $0 · Current $0
29 CFR  1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.  Located in the Park Headquarters building in front of a gray filing cabinet, six portable fire extinguishers were sitting on the floor and were not mounted, located, or identified so that they were readily accessible to employees. Employees are exposed to a fire hazard that could lead to smoke inhalation or burns.
Recent events (1)
  • — Z (S) $0

View U. S. Dept. of Defense - U. S. Army Corp. of Engineers - Warm Springs DAM's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 346381718.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.