JACKSONVILLE, FL —
OSHA Inspection: OTR WHEEL ENGINEERING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of OTR WHEEL ENGINEERING, INC. in 940 EASTPORT RD, JACKSONVILLE, FL 32218 (NAICS 336399). OSHA activity number 342710142.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OTR WHEEL ENGINEERING, INC.
- Site address
- 940 EASTPORT RD
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32218
- Mailing
- 940 EASTPORT RD, JACKSONVILLE, FL 32218
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336399
- Employees
- 217
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.134 C02 I
- Issued
- Nov 1, 2017
- Penalty
- Initial $3,586 · Current $3,586
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a. On or about October 19, 2017, the employer provided and had available for voluntary use by the employees N95 dust/particulate respirators and had not provided them with the 29 CFR 1910.134 Appendix D mandatory information. OTR Wheel Engineering, Inc. (formally known as Long's Wheel & Rim, Inc.) was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.134(c)(2)(i), which was contained in OSHA inspection number 1057178, citation number 2, item number 1-a and was affirmed as a final order on August 4, 2015, with respect to a workplace located at 940 Eastport Road, Jacksonville, Florida 32218.
Recent events (2)
- — I (R) $3586
- — Z (R) $3586
1910.107 B05 I
- Issued
- Nov 1, 2017
- Abate by
- Nov 29, 2017
- Penalty
- Initial $1,006 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained: a. On or about October 19, 2017, inside the facility spray paint booth, CSHO observed an employee (Painter) using a spray paint gun that was discharging flammable paints and thinners with no visible gauges, audible alarms or pressure activated devices installed in paint spray booth to indicate or ensure that the required air speed was maintained to prevent the accumulation of flammable vapors, thereby exposing the employee to fire and explosion hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $1006
1910.107 B08
- Issued
- Nov 1, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(8): Each spray booths was not separated from other operations by not less than 3 feet, or by a greater distance, or by such partition or wall as to reduce the danger from juxtaposition of hazardous operations: a. On or about October 19, 2017, outside of the facility spray paint booth, CSHO observed the storage of flammable chemicals (three 55 gallon drums of Xylene and waste paints) stored within 14-inches of the spray paint booth, exposing employees to fire and explosion hazards in the event of catastrophic event occurring at the spray paint booth or the chemical storage operational areas.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 I05 IV
- Issued
- Nov 1, 2017
- Abate by
- Nov 29, 2017
- Penalty
- Initial $1,006 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(i)(5)(iv): The employer did not ensure that compressors used to supply breathing air to respirators were constructed and situated so as to have a tag maintained at the compressor containing the most recent change date and the signature of the person authorized by the employer to perform the change: a. On or about October 19, 2017, the employer did not ensure that compressor used to supply breathing air to respirators had a tag maintained at the compressor containing the most recent change date and the signature of the person authorized by the employer to perform the change, thereby exposing a painting employee to respiratory illness or injury.
Recent events (2)
- — I (O) $0
- — Z (O) $1006
1910.134 I06
- Issued
- Nov 1, 2017
- Abate by
- Nov 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(6): For compressors that are not oil-lubricated, the employer did not ensure that carbon monoxide levels in the breathing air did not exceed 10 ppm: a. On or about October 19, 2017, the employer did not ensure that compressor used to supply breathing air to employee respirators did not exceed carbon monoxide levels of 10 ppm, thereby exposing a painting employee to respiratory illness or injury.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at OTR Wheel Engineering, INC.
View OTR Wheel Engineering, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 336399)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342710142.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.