On , OSHA opened a complaint safety inspection of OTR WHEEL ENGINEERING, INC. in 940 EASTPORT RD, JACKSONVILLE, FL 32218 (NAICS 336399). OSHA activity number 342710142.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch OTR Wheel Engineering, INC. — free Get an email when a new federal OSHA severe-injury report for OTR Wheel Engineering, INC. is published. One employer, no account, unsubscribe in one click.
Site address
940 EASTPORT RD
City
JACKSONVILLE
State
FL
ZIP
32218
Mailing
940 EASTPORT RD, JACKSONVILLE, FL 32218
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
217
Ownership type
A

5 citations on file for this inspection.

1910.134 C02 I

Repeat 1 instance 9 exposed
Issued
Nov 1, 2017
Penalty
Initial $3,586 · Current $3,586
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  a. On or about October 19, 2017, the employer provided and had available for voluntary use by the employees N95 dust/particulate respirators and had not provided them with the 29 CFR 1910.134 Appendix D mandatory information.  OTR Wheel Engineering, Inc. (formally known as Long's Wheel & Rim, Inc.) was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.134(c)(2)(i), which was contained in OSHA inspection number 1057178, citation number 2, item number 1-a and was affirmed as a final order on August 4, 2015, with respect to a workplace located at 940 Eastport Road, Jacksonville, Florida 32218.
Recent events (2)
  • — I (R) $3586
  • — Z (R) $3586

1910.107 B05 I

Other-than-serious 1 instance 1 exposed
Issued
Nov 1, 2017
Abate by
Nov 29, 2017
Penalty
Initial $1,006 · Current $0 Reduced
29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained:  a. On or about October 19, 2017, inside the facility spray paint booth, CSHO observed an employee (Painter) using a spray paint gun that was discharging flammable paints and thinners with no visible gauges, audible alarms or pressure activated devices installed in paint spray booth to indicate or ensure that the required air speed was maintained to prevent the accumulation of flammable vapors, thereby exposing the employee to fire and explosion hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1006

1910.107 B08

Other-than-serious 1 instance 13 exposed
Issued
Nov 1, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(8): Each spray booths was not separated from other operations by not less than 3 feet, or by a greater distance, or by such partition or wall as to reduce the danger from juxtaposition of hazardous operations:  a. On or about October 19, 2017, outside of the facility spray paint booth, CSHO observed the storage of flammable chemicals (three 55 gallon drums of Xylene and waste paints) stored within 14-inches of the spray paint booth, exposing employees to fire and explosion hazards in the event of catastrophic event occurring at the spray paint booth or the chemical storage operational areas.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 I05 IV

Other-than-serious 1 instance 1 exposed
Issued
Nov 1, 2017
Abate by
Nov 29, 2017
Penalty
Initial $1,006 · Current $0 Reduced
29 CFR 1910.134(i)(5)(iv): The employer did not ensure that compressors used to supply breathing air to respirators were constructed and situated so as to have a tag maintained at the compressor containing the most recent change date and the signature of the person authorized by the employer to perform the change:  a. On or about October 19, 2017, the employer did not ensure that compressor used to supply breathing air to respirators had a tag maintained at the compressor containing the most recent change date and the signature of the person authorized by the employer to perform the change, thereby exposing a painting employee to respiratory illness or injury.
Recent events (2)
  • — I (O) $0
  • — Z (O) $1006

1910.134 I06

Other-than-serious 1 instance 1 exposed
Issued
Nov 1, 2017
Abate by
Nov 29, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(i)(6): For compressors that are not oil-lubricated, the employer did not ensure that carbon monoxide levels in the breathing air did not exceed 10 ppm:  a. On or about October 19, 2017, the employer did not ensure that compressor used to supply breathing air to employee  respirators did not exceed carbon monoxide levels  of 10 ppm, thereby exposing a painting employee to respiratory illness or injury.