Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BASKI WATER INSTRUMENTS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of BASKI WATER INSTRUMENTS, INC. in 4002 S. CLAY ST., ENGLEWOOD, CO 80110 (NAICS 333999). OSHA activity number 342726833.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Baski Water Instruments, INC. — free Get an email when a new federal OSHA severe-injury report for Baski Water Instruments, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4002 S. CLAY ST.
City
ENGLEWOOD
State
CO
ZIP
80110
Mailing
4002 S. CLAY ST., ENGLEWOOD, CO 80110
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333999
Employees
85
Ownership type
A

4 citations on file for this inspection.

1910.94 A04 III

Serious Gravity 5 1 instance 85 exposed
Issued
Dec 8, 2017
Abate by
Jun 12, 2018
Penalty
Initial $6,338 · Current $3,169 Reduced
29 CFR 1910.94(a)(4)(iii)  The air exhausted from blast-cleaning equipment was not discharged through dust collecting equipment. Dust collectors were not set up so that the accumulated dust can be emptied and removed without contaminating other working areas:    a) On or about October 13, 2017, and at times prior, employees were exposed to respiratory hazards due to respirable dust discharged from blast-cleaning equipment that did not have dust collecting equipment.  Dust was discharged through the fan outdoors in proximity to the employee break area and employee's personal vehicles.  Accumulated used media was not collected in a manner that prevented contamination of other working areas.  Used media settled in areas outside of the abrasive blasting enclosure, in the respirator storage area.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $3169
  • — Z (S) $6338

1910.134 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 8, 2017
Abate by
Feb 20, 2018
Penalty
Initial $6,338 · Current $3,169 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    (a) On or about October 13, 2017, and at times prior, employees were exposed to respiratory hazards (including but not limited to: respirable dust, solvents such as xylene, ethyl benzene, or methyl ethyl ketone) due to lack of a written program detailing procedures for a workplace specific Respiratory Protection Program.     Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $3169
  • — Z (S) $6338

1910.134 I07

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 8, 2017
Abate by
Feb 20, 2018
Penalty
Initial $0 · Current $0

Hazardous substances 0560

29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both:    a) On or about October 13, 2017, and at times prior, employees were potentially exposed to carbon monoxide and thermal injury due to lack of a high-temperature alarm and carbon monoxide alarm on the supplied air line of the Bullard 41P2 air cleaner and Bullard 88VX abrasive blasting hood.    Note:  If only a high-temperature alarm is used, the air supply should be monitored to prevent carbon monoxide in the breathing air to exceed 10 ppm.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.94 A03 I E 1

Deleted Other-than-serious 1 instance 85 exposed
Issued
Dec 8, 2017
Abate by
Jan 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.94(a)(3)(i)(e)(1):   Doors to abrasive blasting enclosures were not flanged and tight when closed.  a) On or about October 13, 2017, and at times prior, employees were exposed to respiratory hazards from respirable particulates not otherwise specified due to lack of a flanged and tight door to the abrasive blasting enclosure.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Baski Water Instruments, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342726833.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.