SAN ANTONIO, TX —
OSHA Inspection: ULTRAFRYER SYSTEMS, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ULTRAFRYER SYSTEMS, LLC in 302 SPENCER LN., SAN ANTONIO, TX 78201 (NAICS 333318). OSHA activity number 342729209.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ULTRAFRYER SYSTEMS, LLC
- Site address
- 302 SPENCER LN.
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78201
- Mailing
- 302 SPENCER LN., SAN ANTONIO, TX 78201
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333318
- Employees
- 97
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.134 I07
- Issued
- Jan 3, 2018
- Penalty
- Initial $6,338 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both: Finishing Area, Satin Finish Room: On or about October 27, 2017, and at times prior thereto, employee(s) were exposed to inhalation hazards from the use of supplied air respirators with an oil-lubricated compressor, and neither a carbon monoxide alarm nor carbon monoxide monitoring procedures were in use.
Recent events (2)
- — I (S) $2500
- — Z (S) $6338
1910.243 C01
- Issued
- Jan 3, 2018
- Penalty
- Initial $7,605 · Current $3,050 Reduced
General-duty citation text
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4)(a): Finishing Area: On or about October 27, 2017, and at times prior thereto, employee(s) were exposed to a caught in hazard while working with a Man Guard Grinder that did not have a safety shield or guard in place at the point of operation.
Recent events (2)
- — I (S) $3050
- — Z (S) $7605
1910.303 G02 I
- Issued
- Jan 3, 2018
- Abate by
- Jan 16, 2018
- Penalty
- Initial $3,802 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): Finishing Area, Satin Finish Room: On or about October 27, 2017, and at times prior thereto, employee(s) were exposed to electrical hazards while using a Zero Blast-N-Peen 4000 Dust Collector that had an electrical cover missing.
Recent events (2)
- — I (S) $1500
- — Z (S) $3802
1910.134 C01
- Issued
- Jan 3, 2018
- Abate by
- Jan 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a). Finishing Area: On or about October 27, 2017, and at times prior thereto, employee(s) were exposed to respiratory hazards while working on vat assemblies without a respiratory program to address key issues such as, but not limited to, training, fit testing, and medical evaluation for employees required to use N95 filtering face piece respirators. (b). Finishing Area, Satin Finish Room: On or about October 27, 2017, and at times prior thereto, employee(s) were exposed to respiratory hazards while working on vat assemblies without a respiratory program to address key issues such as, but not limited to, training, fit testing, and medical evaluation for employees required to use a RPB Nova supplied air respirator.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Ultrafryer Systems, LLC