DELHI, NY —
OSHA Inspection: FRIESLANDCAMPINA INGREDIENTS NORTH AMERICA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FRIESLANDCAMPINA INGREDIENTS NORTH AMERICA, INC. in 40196 NY-10, DELHI, NY 13753 (NAICS 311999). OSHA activity number 342739067.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FRIESLANDCAMPINA INGREDIENTS NORTH AMERICA, INC.
- Site address
- 40196 NY-10
- City
- DELHI
- State
- NY
- ZIP
- 13753
- Mailing
- 40196 NY-10, DELHI, NY 13753
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311999
- Employees
- 120
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.22 D01
- Issued
- Apr 11, 2018
- Abate by
- May 7, 2018
- Penalty
- Initial $4,989 · Current $4,450 Reduced
General-duty citation text
29 CFR 1910.22(d)(1): Walking-working surfaces were not maintained in a safe condition: a) On or about 10/25/2017, Manufacturing Areas: Yellow, plastic, step stools were in use with the anti slip surface deteriorated and/ or removed. Abatement certification is required for this item.
Recent events (2)
- — I (S) $4450
- — Z (S) $4989
1910.25 E02
- Issued
- Apr 11, 2018
- Abate by
- Jul 31, 2018
- Penalty
- Initial $4,989 · Current $4,450 Reduced
General-duty citation text
29 CFR 1910.25(e)(2): Ship stairs were not provided with open risers: a) On or about 10/25/2017, Tower Dryer Area: Stairs to the inline pan were not provided with an open back. Abatement certification is required for this item.
Recent events (2)
- — I (S) $4450
- — Z (S) $4989
1910.28 B03 I
- Issued
- Apr 11, 2018
- Abate by
- Jul 31, 2018
- Penalty
- Initial $4,989 · Current $4,450 Reduced
General-duty citation text
29 CFR 1910.28(b)(3)(i): The employer did not ensure each employee is protected from falling through any hole that is 4 feet (1.2 m) or more above a lower level by one or more of the following: covers, guardrail systems, travel restraint systems, or personal fall arrest systems, as required by sub-items A through D of this section: a) On or about 10/25/2017, V Bottom Dryer: A second level platform had an unguarded opening between the sloped dryer wall and the platform. Abatement certification is required for this item.
Recent events (2)
- — I (S) $4450
- — Z (S) $4989
1910.29 B01
- Issued
- Apr 11, 2018
- Abate by
- Jul 31, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.29(b)(1): The top edge height of top rails, or equivalent guardrail system members, were not 42 inches, plus or minus 3 inches, above the walking-working surface: a) On or about 10/25/2017, V Bottom Dryer: A second level platform was lacking a top rail at the equipment end. b) On or about 12/21/2017, Warehouse Area: The top rail of a chain guard rail system was at a height of 29 inches and was located next to the ladderway access to the dust collection and storage area. Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.28 B03 IV
- Issued
- Apr 11, 2018
- Abate by
- Jul 31, 2018
- Penalty
- Initial $6,652 · Current $5,389 Reduced
General-duty citation text
29 CFR 1910.28(b)(3)(iv): The employer did not ensure each employee was protected from falling into a ladderway floor hole or ladderway platform hole by a guardrail system and toeboards erected on all exposed sides, except at the entrance to the hole, where a self-closing gate or an offset must be used: a) On or about 10/25/2017, Production Area: There was no self closing gate or offset provided at the ladderway entrance to the CIP platform. b) On or about 10/25/2017, Production Area: There was no self closing gate or offset provided at the ladderway entrance to a platform for DT1 and DT2 tanks. c) On or about 10/25/2017: Tower Dryer: There was no self closing gate or offset provided at a ladderway entrance on a tower dryer platform. d) On or about 10/25/2017, Production Area: There was no self closing gate or offset provided at the ladderway entrance to the Veghel Kettle platform. e) On or about 12/21/2017, Warehouse Area: There was no self closing gate or offset provided for the ladderway access to the dust collection and storage area. Abatement certification is required for these items.
Recent events (2)
- — I (S) $5389
- — Z (S) $6652
1910.37 A02
- Issued
- Apr 11, 2018
- Abate by
- Jul 31, 2018
- Penalty
- Initial $6,652 · Current $5,389 Reduced
General-duty citation text
29 CFR 1910.37(a)(2): Exit routes were not arranged so that employees did not have to travel toward a high hazard area: a) On or about 10/25/2017, Lab Area: An emergency exit route from the lab area to the exterior of the building allowed for travel next to a Propane tank. Abatement certification is required for this item.
Recent events (2)
- — I (S) $5389
- — Z (S) $6652
1910.106 D04 I
- Issued
- Apr 11, 2018
- Abate by
- May 31, 2018
- Penalty
- Initial $6,652 · Current $6,651 Reduced
General-duty citation text
29 CFR 1910.106(d)(4)(i): Opening(s) from inside flammable and combustible storage room(s) into other rooms or buildings were not provided with noncombustible liquid tight raised seal or ramp at least 4 inches in height. Opening(s) from inside flammable and combustible storage room(s) were not provided with approved self-closing fire doors: a) On or about 10/25/2017: Flammable Storage Room: The flammable storage room was equipped with a man door that was not self closing, and there was no raised lip or seal at the entryway to the flammable storage room. Abatement certification is required for this item.
Recent events (2)
- — I (S) $6651
- — Z (S) $6652
1910.106 D04 IV
- Issued
- Apr 11, 2018
- Abate by
- May 31, 2018
- Penalty
- Initial $6,652 · Current $0 Reduced
General-duty citation text
29 CFR 1910.106(d)(4)(iv): Inside flammable liquid storage rooms were not provided with either a gravity or a mechanical exhaust ventilation system: a) On or about 10/25/2017: Flammable Storage Room: The flammable storage room was not provided with ventilation that would provide at least six air changes per hour. Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $6652
1910.305 E01
- Issued
- Apr 11, 2018
- Abate by
- Jul 31, 2018
- Penalty
- Initial $6,652 · Current $5,389 Reduced
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures were not weatherproof in wet locations: a) On or about 10/25/2017, Manufacturing Areas: Electric outlets exposed to water were not weatherproof. Abatement certification is required for this item.
Recent events (2)
- — I (S) $5389
- — Z (S) $6652
1910.147 C06 I
- Issued
- Apr 11, 2018
- Abate by
- May 31, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 11/3/2017, Throughout the facility: No periodic review of the companies energy control procedures was performed. Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Frieslandcampina Ingredients North America, INC.
View Frieslandcampina Ingredients North America, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311999)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342739067.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.